Document revision date: 19 July 1999 | |
Previous | Contents | Index |
The SHOW POOL/PAGED/HEADER command displays only the name of each block allocated from paged pool, its starting address, its size, and the first four longwords of its contents.
#4 |
---|
SDA SHOW POOL/RING_BUFFER (Non-Paged Pool History Ring-Buffer (512 entries: Most recent first) Packet Adr Size Type Subtype Caller's PC Routine called Entry Adr -------- ----- ----- ---- -------- --------------- -------- DA9EE5C0 168 IRP 3 D8012BF1 EXE$DEANONPAGED DA4C7750 DAA27EC0 192 DSRV 3 DA591941 EXE$DEANONPAGED DA4C7740 DAD47B40 168 IRP 0 DA591918 EXE$DEANONPAGED DA4C7730 DAAB5400 24 FRK 52 DA590252 EXE$DEANONPAGED DA4C7720 DAAB5400 24 TQE 0 DA591276 EXE$ALONONPAGED DA4C7710 DAD47B40 168 IRP 64 DA59184A EXE$ALONONPAGED DA4C7700 . . . DAA66500 172 IRP 64 DB251C80 EXE$ALONONPAGED DA4C7770 DAA32300 192 CIMSG 0 DA54C2C8 EXE$DEANONPAGED DA4C7760 |
This example of the SHOW POOL/RING_BUFFER command displays the contents of the nonpaged pool history ring buffer, with the most recent entries displayed first.
#5 |
---|
SDA SHOW POOL/STATISTICS List head List Alloc. Alloc. Address Size Attempts Failures Deallocs. -------- ----- ---------- ---------- ---------- D80A9030 64 2077039 1121 2073964 D80A9038 128 6323789 4502 6309357 D80A9040 192 21085351 1903 21078538 D80A9048 256 502388 2025 499705 D80A9050 320 1372168 3512 1367707 D80A9058 384 32649 774 31899 D80A9060 448 2463316 1025 2462243 D80A9068 512 357170 2181 354754 D80A9070 576 293998 2438 291476 D80A9078 640 168145 645 167482 D80A9080 704 83645 2043 81547 D80A9088 768 34852 120 34726 D80A9090 832 21263 44 21215 . . . D80A9290 4928 2305645 3283 2302249 D80A9298 4992 9 0 6 D80A92A0 5056 0 0 0 D80A92A8 5120 1 0 0 |
This example of the SHOW POOL/STATISTICS command displays usage statistics about each pool list.
#6 |
---|
SDA SHOW POOL/SUMMARY Summary of non-paged pool contents 145 UNKNOWN = 191616 (18%) 2 ADP = 1280 (0%) 35 ACB = 2624 (0%) 3 AQB = 192 (0%) 17 CRB = 2368 (0%) 16 DDB = 2048 (0%) 355 FCB = 113600 (11%) 3 FRK = 18240 (1%) 16 IDB = 1088 (0%) 42 IRP = 8064 (0%) 20 PCB = 10240 (1%) 48 TQE = 3072 (0%) 70 UCB = 21696 (2%) 5 VCB = 1280 (0%) 299 WCB = 51008 (5%) 287 BUFIO = 112128 (11%) 5 TYPAHD = 1920 (0%) 2 MVL = 4736 (0%) 3 NET = 4160 (0%) 15 CXB = 23616 (2%) 5 NDB = 2112 (0%) 14 DPT = 132928 (13%) . . . Total space used = 1016896 out of 1068032 total bytes, 51136 bytes left Total space utilization = 95% Summary of paged pool contents 33 UNKNOWN = 36480 (15%) 1 PQB = 2256 (0%) 224 GSD = 14240 (6%) 153 KFE = 10864 (4%) 3 MTL = 96 (0%) 118 KFRH = 46736 (20%) 1 RSHT = 528 (0%) 1 XWB = 18048 (7%) 225 LNM = 16720 (7%) 4 KFD = 224 (0%) 1 KFPB = 16 (0%) 2 CIA = 29264 (12%) 1 CHIP = 9216 (4%) 41 ORB = 5248 (2%) 2 ARB = 34912 (15%) 1 PTC = 3072 (1%) 7 OCB = 1344 (0%) 1 PGD = 208 (0%) Total space used = 229472 out of 524800 total bytes, 295328 bytes left Total space utilization = 43% |
This example of the SHOW POOL/SUMMARY command displays an allocation summary for each region of pool.
Displays those portions of the port descriptor table (PDT) that are port independent.
SHOW PORTS [/qualifier[,...]]
None.
/ADDRESS=pdt-address
Displays the specified port descriptor table (PDT).10/BUS[=bus-address]
Displays BUS (LAN device) structure data./CHANNEL[=channel-address]
Displays channel (CH) data./DEVICE
Displays the network path description for a channel./MESSAGE
Displays the message data associated with a virtual circuit (VC)./NODE=name
Displays virtual circuit (VC) information associated with the named node on the specified PDT. You must use this qualifier with /ADDRESS qualifier.
/VC[=vc-address]
Displays the virtual circuit data.
The SHOW PORTS command provides port-independent information from the port descriptor table (PDT) for those CI ports with full SCS connections. This information is used by all system communications services (SCS) port drivers.Note that the SHOW PORTS command does not display similar information about UDA ports, BDA ports, and similar controllers.
The SHOW PORTS command also defines symbols for PEDRIVER based on the cluster configuration. These symbols include the following information:
- Virtual circuit (VC) control blocks for each of the remote systems
- BUS data structure for each of the local LAN adapters
- Some of the data structures used by both PEDRIVER and the LAN drivers
The following symbols are defined automatically:
Symbol Explanation or Example VC_nodename VC_NODE1, address of the local node's virtual circuit to node NODE1 CH_nodename The preferred channel for the virtual circuit; for example, CH_NODE1, address of the local node's preferred channel to node NODE1 BUS_busname BUS_ETA, address of the local node's BUS structure associated with LAN adapter ETA0 PE_PDT Address of PEDRIVER's port descriptor table MGMT_VCRP_busname MGMT_VCRP_ETA, address of the management VCRP for BUS ETA HELLO_VCRP_busname HELLO_VCRP_ETA, address of the HELLO message VCRP for BUS ETA VCIB_busname VCIB_ETA, address of the VCIB for BUS ETA UCB_LAVC_busname UCB_LAVC_ETA, address of the LAN device's UCB used for the local area VAXcluster protocol UCB0_LAVC_busname UCB0_LAVC_ETA, address of the LAN device's template UCB LDC_LAVC_busname LDC_LAVC_ETA, address of the LDC structure associated with LAN device ETA LSB_LAVC_busname LSB_LAVC_ETA, address of the LSB structure associated with LAN device ETA These symbols equate to system addresses for the corresponding data structures. You can use these symbols, or an address, after the equal sign in SDA commands.
The SHOW PORTS command produces several displays. The initial display, the PDT summary page, lists the PDT address, port type, device name, and driver name for each PDT. Subsequent displays provide information taken from each PDT listed on the summary page.
You can use the /ADDRESS qualifier of the SHOW PORTS command to produce more detailed information about a specific port. The first display of the SHOW PORTS/ADDRESS command duplicates the last display of the SHOW PORTS command, listing information stored in the port's PDT. Subsequent displays list information about the port blocks and virtual circuits associated with the port.
#1 |
---|
SDA> SHOW PORTS/ADDR=PE_PDT |
VAXcluster data structures -------------------------- --- Port Descriptor Table (PDT) 806C37A0 --- Type: 03 pe Characteristics: 0000 Msg Header Size 32 Connect 80799F94 Recyclh_Msg_Buf 8079AD8A Max Xfer Bcnt FFFFFFFF Dealloc_Dg_Buf 8079AFDA Request_Data 8079B1CC DG Header Size 288 Disconnect 8079A06B Send_Data 8079B215 Poller Sweep 31 Unmap 8079B510 Send_Dg_Buf 8079B03E Fork Block W.Q. empty Map 8079B111 Send_Msg_Buf 8079AEA8 UCB Address 806C0E50 Map_Bypass 8079B0F8 Send_Cnt_Msg_Buf 8079AEAF ADP Address 00000000 Map_Irp 8079B101 Read_Count 80796D59 Accept 80799FEC Map_Irp_Bypass 8079B0F0 Rls_Read_Count 80796DD3 Alloc_Dg_Buf 8079AFC6 Queue_Dg_Buf 8079AFE0 Mreset 80799C94 Alloc_Msg_Buf 8079AD05 Queue_Mult_Dgs 8079AFE8 Mstart 80799C9E Dealloc_Msg_Buf 8079ADE3 Recycl_Msg_Buf 8079AD94 Stop_Vcs 8079BEDD Dealloc_Msg_Buf_Reg 8079ADF6 Reject 8079A036 Send_Dg_Reg 8079B031 --- Port Block 80B091B0 --- Status: 0001 authorize VC Count: 5 Secs Since Last Zeroed: 311728 SBUF Size 436 LBUF Size 1788 SBUF Count 12 LBUF Count 1 SBUF Max 768 LBUF Max 384 SBUF Quo 13 LBUF Quo 1 SBUF Miss 18 LBUF Miss 12235 SBUF Allocs 499579 LBUF Allocs 16824 SBUFs In Use 0 LBUFs In Use 0 Peak SBUF In Use 14 Peak LBUF In Use 34 SBUF Queue Empty 0 LBUF Queue Empty 0 TR SBUF Queue Empty 0 No SBUF for ACK 0 Bus Addr Bus LAN Address Error Count Last Error Time of Last Error -------- --- ----------------- ----------- ---------- ----------------------- 80B08920 LCL 00-00-00-00-00-00 0 80B08090 ESA AA-00-04-00-33-FD 75 00000334 25-MAR-1993 23:39:28.27 80B008B0 XQA 08-00-2B-0A-6A-6B 12 0000002C 23-MAR-1993 12:43:59.07 80AF6E90 XQB 08-00-2B-08-CB-B8 0 --- Virtual Circuit (VC) Summary --- VC Addr Node SCS ID Lcl ID Status Summary Last Event Time -------- -------- ------ ------ ----------------- ----------------------- 806CD1A0 NODE12 64819 223/DF open,path 1-JAN-1993 00:00:00.03 806CD6E0 NODE13 64856 222/DE open,path 1-JAN-1993 00:00:07. 806CD9A0 NODE14 64587 221/DD open,path 22-MAR-1993 18:34:10.18 8070D530 NODE15 64555 220/DC open,path 22-MAR-1993 18:57:33. 8074AB60 NODE16 64841 219/DB open,path 25-MAR-1993 20:42:38.20The SHOW PORTS/ADDRESS command displays the port descriptor table (PDT) structure, some of the fields in the PORT structure, the BUS summary, and the virtual circuit summary.
#2 |
---|
SDA>SHOW PORTS/BUS=BUS_ESA |
VAXcluster data structures -------------------------- --- BUS: 80B08090 (ESA) Device: ES_LANCE LAN Address: AA-00-04-00-33-FD--- LAN Hardware Address: 08-00-2B-12-AE-A1 Status: 00000A03 run,online,xmt_chaining_disabled,restart ------- Transmit ------ ------- Receive ------- ---- Structure Addresses --- Msg Xmt 434107 Msg Rcv 1170090 PORT Address 80B091B0 Mcast Msgs 103939 Mcast Msgs 859601 VCIB Addr 80B08248 Mcast Bytes 13304192 Mcast Bytes 96272072 HELLO Message Addr 80B082D8 Bytes Xmt 59789962 Bytes Rcv 146674695 BYE Message Addr 80B08468 Outstand I/Os 0 Buffer Size 1424 Delete BUS Rtn Adr 8079E424 Xmt Errors 75 Rcv Ring Size 8 Last Xmt Error 00000334 Time of Last Xmt Error 25-MAR-1993 23:39:28.27 --- Receive Errors ---- ------ BUS Timer ------ ----- Datalink Events ------ TR Mcast Rcv 0 Handshake TMO 8079FA50 Last 22-MAR-1993 18:25:25.12 Rcv Bad SCSID 0 Listen TMO 8079FA54 Last Event 00001202 Rcv Short Msg 0 HELLO timer 1 Port Usable 1 Fail CH Alloc 0 HELLO Xmt err 38 Port Unusable 0 Fail VC Alloc 0 Address Change 1 Wrong PORT 0 Port Restart Fail 0The SHOW PORTS/BUS=BUS_id command displays the data for the specified BUS structure. The last event time is at the top of the lower right-hand column. If an error was counted, the last error time is displayed under Xmt Errors. The normal status is: RUN, ONLINE, and RESTART.
The Xmt Error field indicates a problem detected during transmission of a message. The error rate should be less than one per hour.
#3 |
---|
SDA> SHOW PORTS/VC=VC_BREE |
VAXcluster data structures -------------------------- --- Virtual Circuit (VC) 806CD6E0 --- Remote System Name: BREE (0:VAX) Remote SCSSYSTEMID: 64856 Local System ID: 222 (DE) Status: 0005 open,path ------ Transmit ------- ------ VC Closures ---- ---- Congestion Control ---- Msg Xmt 216686 SeqMsg TMO 0 UnAcked Msgs 1 Unsequence 3 CC DFQ Empty 0 Pipe Quota Reached 33 Sequence 149643 Topology Change 0 CMD Queue Len 0 ReXmt 545 NPAGEDYN Low 0 Max CMD Queue Len 5 Lone ACK 66495 RSVP Threshold 15 Bytes Xmt 33309074 Pipe Quota 31 ------- Receive ------- - Messages Discarded - ----- Channel Selection ---- Msg Rcv 194492 No Xmt Chan 0 Preferred Channel 80704320 Unsequence 1 Rcv Short Msg 0 Delay Time FB7E6F80 Sequence 178905 Illegal Seq Msg 0 Buffer Size 1424 ReRcv 30 Bad Checksum 0 Channel Count 6 Lone ACK 15531 TR DFQ Empty 0 Channel Selections 3920 Cache 26 TR MFQ Empty 0 Protocol 1.3.0 Ill ACK 0 CC MFQ Empty 0 Open 1-JAN-1993 00:00:07.03 Bytes Rcv 52086897 Cache Miss 0 Cls 17-NOV-1858 00:00:00.00 -- Channel Summary for Virtual Circuit (BREE ) 806CD6E0 -- Address Type Xmt Time Size Preferred Best Last State Change -------- --------- -------- ---- --------- -------- ----------------------- 80704320 Preferred FB7E6F80 1424 812 617 22-MAR-1993 18:14:07.01 807043E0 Active FB7E735E 1424 95 4 25-MAR-1993 20:01:15.18 807050D0 Active FB7E7FED 1424 431 0 25-MAR-1993 20:01:15.18 806CD820 Active FB7E728E 1424 868 1470 25-MAR-1993 20:01:15.18 80705010 Active FB7E7043 1424 738 9 25-MAR-1993 20:00:58.17 806CD8E0 Active FB7E7BB5 1424 976 1744 25-MAR-1993 20:00:31.17The SHOW PORTS/VC=VC_id command displays the virtual circuit data for the specified remote node and a channel summary. In this display, the upper center of the display contains the virtual circuit status. The lower right-hand corner contains the virtual circuit open and close times.
The ReXmt field indicates a problem sending messages to the remote system. The error rate per hour should be less than the Pipe Quota field.
The ReRcv field indicates a problem receiving messages from the remote system. The error rate per hour should be less than the Pipe Quota field.
#4 |
---|
SDA> SHOW PORTS/MESSAGE/VC=address |
This SHOW PORTS command displays the virtual circuit data for the specified remote node, followed by the message data for the remote node. The virtual circuit message display shows the counters for the following items:
- Sequenced message delivery
- Any messages in the process of being transmitted or in the receive cache
The following is an example of part of a display resulting from the SHOW PORTS/MESSAGE/VC=vc-address command:
VAXcluster data structures -------------------------- --- Sequenced Message Counters Virtual Circuit (VC) 806CD6E0 --- NSU: 4457 HAA: 4456 LAR: 4455 HSR: B3AA Cache Mask: 00000000 Messages Waiting for ACKs VCRP adr Len Flgs Seq Ack Message Data -------- ---- ---- ---- ---- ----------------------------------------------- 806CD2E0 137 0B 4456 B3AA 02 7D 00 04 00 0A 00 00 00 09 00 D 75 05 00 67
#5 |
---|
SDA> SHOW PORTS/CHANNEL=CH_BREE |
This SHOW PORTS command displays the data for the specified channel. The normal state is OPEN, with a status of PATH, OPEN, and RMT_HWA_VALID.
In the following example display resulting from this command, the top of the display shows the remote device name, the remote device type, and the channel open and close times.
VAXcluster data structures -------------------------- : PEDRIVER Channel (CH:80704320) for Virtual Circuit (VC:806CD6E0) BREE -- State: 0004 open Status: 0B path,open,rmt_hwa_valid BUS: 80B008B0 (XQA) Lcl Device: XQ_DELQA Lcl LAN Address: 08-00-2B-0A-6A-6B Rmt Name: XQB Rmt Device: XQ_DEQTA Rmt LAN Address: 08-00-2B-13-70-88 Rmt Seq #: 0002 Open:22-MAR-1993 18:14:07.01 Closed:17-NOV-1858 00:00:00.00 ------- Transmit ------ ------- Receive ------- ----- Channel Selection ---- Lcl CH Seq # 0001 Msg Rcv 139205 Average Xmt Time FB879740 Msg Xmt 66707 Mcast Msgs 103906 Remote Buffer Size 1424 Ctrl Msgs 1 Mcast Bytes 10182788 Max Buffer Size 1424 Ctrl Bytes 98 Ctrl Msgs 2 Best Channel 615 Bytes Xmt 9130385 Ctrl Bytes 196 Preferred Channel 810 Rmt Ring Size 31 Bytes Rcv 22654333 Retransmit Penalty 2 --------------- Channel Errors --------------- Xmt Error Penalty 12 Handshake TMO 0 Short CC Msgs 0 ------- Channel Timer ------ Listen TMO 0 Incompat Chan 0 Timer Entry Flink 8079FA3C Bad Authorize 0 No MSCP Srvr 0 Blink 80705010 Bad ECO 0 Disk Not Srvd 0 Last Ring Index 08 Bad Multicast 0 Old TR Msgs 0 Protocol 1.3.0 Topology Change 0 Supported Services 00000000
#6 |
---|
SDA> SHOW PORTS/DEVICE/CHANNEL/VC=vc-address |
This SHOW PORTS command displays the following information:
- Virtual circuit data for the specified remote node
- Channel data
- The network path description for each channel to the remote node
The following is an example of a display resulting from the SHOW PORTS/DEVICE/CHANNEL/VC=vc-address command:
VAXcluster data structures -------------------------- : Network Component List (CLST:80D36440) for Channel (CH:806DC420) -- COMP adr COMP Type Description -------- --------- --------------------------------------------------------- 80D30010 NODE SGRPOP:VAXstation 3300; RDO3-4/U10 80CC9300 ADAPTER ESA; SGRPOP:VAXstation 3300; RDO3-4/U10 (08-00-2B-12-AE-A1) 80D3CDB0 COMPONENT RD34C4, I-Cluster Segment DAMPR 80D40380 COMPONENT RD34C4, I-Cluster Segment SELNI 80D36AD0 COMPONENT I-Cluster Segment 80D2D4C0 P COMPONENT RDO3-4 Lab, DIVER: I-Cluster Segment SELNI . . . 80D323F0 NODE PELLNM:rack mounted MicroVAX II; RDO3-4 LabThis display is useful after the local area VAXcluster network failure analysis data has been loaded. After a network failure analysis, this display indicates primary and secondary failed component suspects in the following ways:
- P: Primary suspect
- S: Secondary suspect
- ?: Component that cannot be proved to be working
#7 |
---|
SDA> SHOW PORTS /DEVICE /CHANNEL=address |
This SHOW PORTS command displays the channel data and the network path description if it was provided by the network failure analysis.
#8 |
---|
SDA> SHOW PORTS/BUS/CHANNEL/DEVICE/MESSAGE/VC/ADDRESS=PE_PDT |
This command displays all of the bus structures, all of the virtual circuits and their message counters, and channels, including network path descriptions when available.
#9 |
---|
SDA> SHOW PORTS/ADDR=862C8D80/NAME=DAVID3 VAXcluster data structures -------------------------- --- Virtual Circuit (VC) 862C8D80 --- Remote System Name: DAVID3 (0:VAX) Remote SCSSYSTEMID: 64588 Local System ID: 213 (D5) Status: 0005 open,path ------ Transmit ------- ------ VC Closures ---- ---- Congestion Control ---- Msg Xmt 19 SeqMsg TMO 0 Pipe Quota/Slo/Max 1/31/31 Unsequence 16 CC DFQ Empty 0 Pipe Quota Reached 0 Sequence 3 Topology Change 0 Xmt C/T 0/1 ReXmt 0/0 NPAGEDYN Low 0 RndTrp uS 3000000+0 Lone ACK 0 UnAcked Msgs 0 Bytes Xmt 1058 CMD Queue Len/Max 0/0 ------- Receive ------- - Messages Discarded - ----- Channel Selection ---- Msg Rcv 10 No Xmt Chan 0 Preferred Channel 00000000 Unsequence 16 Rcv Short Msg 0 Delay Time 003266DB Sequence 0 Illegal Seq Msg 0 Buffer Size 1424 ReRcv 0 Bad Checksum 0 Channel Count 2 Lone ACK 0 TR DFQ Empty 0 Channel Selections 9 Cache 0 TR MFQ Empty 0 Protocol 1.3.0 Ill ACK 0 CC MFQ Empty 0 Open 8-FEB-1993 11:30:43.60 Bytes Rcv 440 Cache Miss 0 Cls 8-FEB-1993 11:28:30.69 -- Channel Summary for Virtual Circuit (DAVID3) 862C8D80 -- Address Type Xmt Time Size Preferred Best Last State Change -------- --------- -------- ---- --------- -------- ---------------------- 862CB600 Active 000927BF 1424 3 4 8-FEB-1993 11:30:53.69 862C8F00 Active 000927BF 1424 6 2 8-FEB-1993 11:30:43.60 |
The command in this example displays virtual connect information associated with the DAVID3 node, which is associated with the port descriptor table whose address is 862C8D80.
10 You can find the pdt-address for any active connection on the system in the PDT summary page display of the SHOW PORTS command. This command also defines the symbol PE_PDT. CDT addresses are also stored in many individual data structures related to SCS connections; for instance, in the path block displays of the SHOW CLUSTER/SCS command. |