          Document revision date: 19 July 1999
      
     | 
  
 
  
    
![[Compaq]](../../images/compaq.gif)  | 
    
       
 
 
 
 
      
     | 
  
 
  
    
 
     | 
  
 
 
 
 
OpenVMS RTL Library (LIB$) Manual
LIB$FLT_UNDER
The Floating-Point Underflow Detection routine enables or disables 
floating-point underflow detection for the calling routine activation. 
The previous setting is returned as a function value.
  Note 
No support for arguments passed by 64-bit address reference or for use 
of 64-bit descriptors, if applicable, is planned for this routine. 
     | 
  
 This routine is available on OpenVMS Alpha systems in translated form 
 and is applicable to translated VAX images only.
Format
LIB$FLT_UNDER new-setting 
RETURNS
  
    | OpenVMS usage:  | 
    longword_unsigned | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by value | 
  
The old floating-point underflow enable setting (the previous contents 
of the SF$W_PSW[PSW$V_FU] in the caller's frame).
Argument
new-setting
  
    | OpenVMS usage:  | 
    longword_unsigned | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
New floating-point underflow enable setting. The 
new-setting argument is the address of an unsigned 
byte containing the new setting. Bit 0 set to 1 means enable; bit 0 set 
to 0 means disable.
Description
LIB$FLT_UNDER affects only the current routine activation and does not 
affect any of its callers or any routines that it may call. However, 
the setting does remain in effect for any routines entered through a 
JSB entry point.
The caller's stack frame will be modified by this routine.
Condition Values Returned
None.
Example
  
     | 
  
    
       
      
C+ 
C This Fortran example program shows 
C the use of LIB$FLT_UNDER. 
C- 
 
        INTEGER*4  NEW_SETTING 
        REAL*4  X , Y , Z 
 
        NEW_SETTING = 0 
        X = 1E-20 
        Y = 1E20 
 
        CALL LIB$FLT_UNDER( NEW_SETTING ) 
 
        TYPE *,'First Case: This should not have an underflow exception' 
 
        Z = X / Y 
 
        TYPE *, 'If this lines prints then the underflow exception 
     1  was disabled.' 
        TYPE * 
 
        NEW_SETTING = 1 
        X = 1E-20 
        Y = 1E20 
 
        CALL LIB$FLT_UNDER( NEW_SETTING ) 
 
        TYPE * , 'Second Case: This should have an underflow exception 
     1  and then stop.' 
 
        Z = X / Y 
 
        TYPE * , 'If this line prints, then the underflow exception 
     1  was disabled.' 
 
        END 
 
 
      
      
     | 
  
In this Fortran example, floating-point underflow detection is disabled 
the first time X is divided by Y. The second time, underflow detection 
is enabled, and the program stops because of the error generated.
LIB$FORMAT_DATE_TIME
The Format Date and/or Time routine allows the user to select at run 
time a specific output language and format for a date or time, or both.
Format
LIB$FORMAT_DATE_TIME date-string [,date] [,user-context] 
[,date-length] [,flags] 
RETURNS
  
    | OpenVMS usage:  | 
    cond_value | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by value | 
  
Arguments
date-string
  
    | OpenVMS usage:  | 
    char_string | 
  
  
    | type:  | 
    character string | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by descriptor | 
  
Receives the requested date or time, or both, that has been formatted 
for output according to the currently selected format and language. The 
date-string argument is the address of a descriptor 
pointing to this string.
date
  
    | OpenVMS usage:  | 
    date_time | 
  
  
    | type:  | 
    quadword (unsigned) | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
The date or time, or both, to be formatted for output. The 
date argument is the address of an unsigned quadword 
that contains the absolute date or time, or both to be formatted. If 
you omit this argument, or if you supply a zero passed by value, then 
the current system time is used. Note that the date 
argument must represent an absolute time, not a delta time.
user-context
  
    | OpenVMS usage:  | 
    context | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    modify | 
  
  
    | mechanism: | 
    by reference | 
  
User context that retains the translation context over multiple calls 
to this routine. The user-context argument is the 
address of an unsigned longword that contains this context. The initial 
value of the context variable must be zero. Thereafter, the user 
program must not write to the cell.
The user-context parameter is optional. However, if a 
context cell is not passed, the routine LIB$FORMAT_DATE_TIME may abort 
if two threads of execution attempt to manipulate the context area 
concurrently. Therefore, when calling this routine in situations where 
reentrancy might occur, such as from AST level, Compaq recommends that 
users specify a different context cell for each calling thread.
date-length
  
    | OpenVMS usage:  | 
    longword_signed | 
  
  
    | type:  | 
    longword (signed) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by reference | 
  
Number of bytes of text written to the  date-string 
argument. The date-length argument is the address of a 
signed longword that receives this string length. Note that 
date-length specifies the number of bytes of text, not 
the number of characters, written to date-string.
flags
  
    | OpenVMS usage:  | 
    mask_longword | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
Bit mask that allows the user to specify whether the date, time, or 
both are output. The flags argument is the address of 
an unsigned bit mask containing the specified values. Valid values are 
LIB$M_DATE_FIELDS and LIB$M_TIME_FIELDS.
Default values are determined as follows:
  - If the flags argument is omitted, 
  LIB$FORMAT_DATE_TIME determines which fields to format according to the 
  current definition of LIB$DT_FORMAT.
  
 - If the flags argument is specified, 
  LIB$FORMAT_DATE_TIME uses the flags value to determine 
  which fields to format. That is, the flags argument 
  can be used to override the definition of LIB$DT_FORMAT when specifying 
  which fields should be formatted for output. If the field specified by 
  flags was not assigned a format through the definition 
  of LIB$DT_FORMAT, the standard OpenVMS format is used.
 
Description
The LIB$FORMAT_DATE_TIME routine formats an OpenVMS internal format 
date-time quadword into a textual string of some predefined format. The 
language to be used and the format in which to output the information 
are programmable using either of the following methods.
  - The language and format are programmable at compile time through 
  the use of the routine LIB$INIT_DATE_TIME_CONTEXT.
  
 - The language and format are determined at run time through the 
  translation of the logical names SYS$LANGUAGE
 and LIB$DT_FORMAT.
 
In general, if an application is formatting text for internal storage 
or transmission, the language and format should be specified at compile 
time. If this is the case, use the routine LIB$INIT_DATE_TIME_CONTEXT 
to specify the language and format of your choice.
If an application is formatting text for presentation to a user, the 
logical name method of specifying language and format should be used. 
In this method, the user assigns equivalence names to the logical names 
SYS$LANGUAGE and LIB$DT_FORMAT, thereby selecting the language and 
format of the date and time at run time.
If the logical name method is used, the translations of the logical 
names SYS$LANGUAGE and LIB$DT_FORMAT specify one or more executive mode 
logicals, which in turn must be translated to determine the actual 
format string. These additional logicals supply such things as the 
names of the days of the week and the months in the selected language 
(determined by SYS$LANGUAGE). All of these logicals are predefined, so 
that a non-privileged user can select any one of these languages and 
formats. A user can create his or her own languages and formats; 
however, the CMEXEC, SYSNAME, and SYSPRV privileges are required.
With the exception of SYS$LANGUAGE and LIB$DT_FORMAT, all logical names 
used by this routine must be defined from the executive mode.
See the OpenVMS Programming Concepts Manual for a description of system date and time 
operations as well as a detailed description of the format mnemonics 
used in these routines.
Condition Values Returned
  
    | 
      SS$_NORMAL
     | 
    
      Routine successfully completed.
     | 
  
  
    | 
      LIB$_ABSTIMREQ
     | 
    
      Absolute time required.
     | 
  
  
    | 
      LIB$_DEFFORUSE
     | 
    
      Default format used; unable to determine the desired format.
     | 
  
  
    | 
      LIB$_ENGLUSED
     | 
    
      English used; unable to determine or use the specified language.
     | 
  
  
    | 
      LIB$_REENTRANCY
     | 
    
      Reentrant invocation with same context variable.
     | 
  
  
    | 
      LIB$_STRTRU
     | 
    
      Output string truncated.
     | 
  
  
    | 
      LIB$_UNRFORCOD
     | 
    
      Unrecognized format code.
     | 
  
Any condition values returned by the $NUMTIM system service, or RTL 
routines LIB$GET_VM, LIB$GET_VM_64, LIB$ANALYZE_SDESC, or 
LIB$ANALYZE_SDESC_64.
LIB$FORMAT_SOGW_PROT
The Format Protection Mask routine translates a protection mask into a 
formatted string.
Format
LIB$FORMAT_SOGW_PROT protection-mask, [access-names], 
[ownership-names], [ownership-separator], [list-separator], 
protection-string, [protection-length] 
RETURNS
  
    | OpenVMS usage:  | 
    cond_value | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by value | 
  
Arguments
protection-mask
  
    | OpenVMS usage:  | 
    protection | 
  
  
    | type:  | 
    word (unsigned) | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
The address of a word that holds a 16-bit protection mask to be 
translated.
access-names
  
    | OpenVMS usage:  | 
    access_names  | 
  
  
    | type:  | 
    array [0..31] of quadword string descriptor  | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
The address of the access name table for the associated object class. 
For example, it is the value returned in accnam by 
LIB$GET_ACCNAM. This parameter defaults to the access name table for the 
FILE object class.
ownership-names
  
    | OpenVMS usage:  | 
    char_string  | 
  
  
    | type:  | 
    array [0..3] of quadword string descriptor  | 
  
  
    | access:  | 
    read only  | 
  
  
    | mechanism: | 
    by reference | 
  
The address of a vector of 4 quadword descriptors that points to the 
ownership name. The default value is the full ownership category names 
(System, Owner, Group, World).
ownership-separator
  
    | OpenVMS usage:  | 
    char_string | 
  
  
    | type:  | 
    character-coded text string | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by descriptor | 
  
The address of a descriptor that points to the ownership separator 
string. The separator string is inserted after the ownership name to 
introduce a nonempty set of access names. By default, the value is 
": " (the colon and space characters).
list-separator
  
    | OpenVMS usage:  | 
    char_string | 
  
  
    | type:  | 
    character-coded text string | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by descriptor | 
  
The address of a descriptor that points to the list separator string. 
The list separator string is inserted between ownership-access type 
pairs. By default, the value is ", " (the comma and space 
characters).
protection-string
  
    | OpenVMS usage:  | 
    char_string | 
  
  
    | type:  | 
    character-coded text string | 
  
  
    | access:  | 
     write only | 
  
  
    | mechanism: | 
    by descriptor | 
  
The address of a character-string descriptor that receives the output 
of the routine call. The protection-string argument 
points to the formatted protection string at the end of a call. The 
protection string has the following components repeated for each of: 
System, Owner, Group, World:
 ownership-name[ownership-separator][access-types][list-separator]
 An example of a formatted protection string is
 System: RWED, Owner: RWED, Group: RW, World: R
protection-length
  
    | OpenVMS usage:  | 
    word_signed | 
  
  
    | type:  | 
    word (signed) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by reference | 
  
The address of a word that receives the length of the string returned 
in the protection-string argument.
Description
LIB$FORMAT_SOGW_PROT translates a 16-bit protection mask into a 
formatted string. This routine works for any protected object class by 
specifying the correct access name table. The address of the access 
name table can be obtained from the LIB$GET_ACCNAM routine.
Several formatting options are available. The caller can specify 
ownership names, ownership separators, or list separators.
Condition Values Returned
  
    | 
      SS$_NORMAL
     | 
    
      Routine successfully completed.
     | 
  
  
    | 
      LIB$_INVARG
     | 
    
      Required parameter missing.
     | 
  
  
    | 
      LIB$_WRONGNUMARG
     | 
    
      Wrong number of arguments.
     | 
  
  
    | 
      STR$_TRU
     | 
    
      String truncation warning.
     | 
  
LIB$FREE_DATE_TIME_CONTEXT
The Free the Context Area Used When Formatting Dates and Times for 
Input or Output routine frees the virtual memory associated with the 
context area used by the date/time input and output formatting routines.
Format
LIB$FREE_DATE_TIME_CONTEXT [user-context] 
RETURNS
  
    | OpenVMS usage:  | 
    cond_value | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by value | 
  
Argument
user-context
  
    | OpenVMS usage:  | 
    context | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    modify | 
  
  
    | mechanism: | 
    by reference | 
  
User context that retains the translation context over multiple calls 
to the date/time input and output formatting routines. The 
user-context argument is the address of an unsigned 
longword that contains this context. If the 
user-context argument was not specified in the call to 
LIB$FORMAT_DATE_TIME, LIB$CONVERT_DATE_STRING, or 
LIB$GET_MAXIMUM_DATE_LENGTH, then no argument should be supplied when 
calling this routine.
Description
The LIB$FREE_DATE_TIME_CONTEXT routine frees the virtual memory 
associated with the context area used by the date/time input and output 
formatting routines. A call to this routine is optional, since the same 
functions are performed at image exit.
Condition Values Returned
  
    | 
      SS$_NORMAL
     | 
    
      Routine successfully completed.
     | 
  
Any condition value returned by LIB$FREE_VM. If one of these condition 
values is returned, it indicates either an internal coding error or 
that memory was corrupted by the user's program.
LIB$FREE_EF
The Free Event Flag routine frees a local event flag previously 
allocated by LIB$GET_EF or by LIB$RESERVE_EF. LIB$FREE_EF is the 
complement of LIB$GET_EF.
Format
LIB$FREE_EF event-flag-number 
RETURNS
  
    | OpenVMS usage:  | 
    cond_value | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by value | 
  
Argument
event-flag-number
  
    | OpenVMS usage:  | 
    ef_number | 
  
  
    | type:  | 
    longword integer (unsigned) | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
Event flag number to be deallocated by LIB$FREE_EF. The 
event-flag-number argument is the address of a signed 
longword integer that contains the event flag number, which is the 
value allocated to the user by LIB$GET_EF or LIB$RESERVE_EF.
Description
When a local event flag allocated by calling LIB$GET_EF or 
LIB$RESERVE_EF is no longer needed, LIB$FREE_EF should be called to 
free the event flag for use by other routines.
See the OpenVMS Programming Concepts Manual for more information.
Condition Values Returned
  
    | 
      SS$_NORMAL
     | 
    
      Routine successfully completed.
     | 
  
  
    | 
      LIB$_EF_ALRFRE
     | 
    
      Event flag already free.
     | 
  
  
    | 
      LIB$_EF_RESSYS
     | 
    
      Event flag reserved to system. This error occurs if the event flag 
      number is outside the ranges of 1 to 23 and 32 to 63.
     | 
  
LIB$FREE_LUN
The Free Logical Unit Number routine releases a logical unit number 
allocated by LIB$GET_LUN to the pool of available numbers. LIB$FREE_LUN 
is the complement of LIB$GET_LUN.
Format
LIB$FREE_LUN logical-unit-number 
RETURNS
  
    | OpenVMS usage:  | 
    cond_value | 
  
  
    | type:  | 
    longword (unsigned) | 
  
  
    | access:  | 
    write only | 
  
  
    | mechanism: | 
    by value | 
  
Argument
logical-unit-number
  
    | OpenVMS usage:  | 
    longword_signed | 
  
  
    | type:  | 
    longword integer (signed) | 
  
  
    | access:  | 
    read only | 
  
  
    | mechanism: | 
    by reference | 
  
Logical unit number to be deallocated. The 
logical-unit-number argument is the address of a 
signed longword integer that contains this logical unit number, which 
is the value previously returned by LIB$GET_LUN.
Description
When a logical unit number allocated by calling LIB$GET_LUN is no 
longer needed, it should be released for use by other routines.
This routine is useful only in BASIC or Fortran programs.
Condition Values Returned
  
    | 
      SS$_NORMAL
     | 
    
      Routine successfully completed.
     | 
  
  
    | 
      LIB$_LUNALRFRE
     | 
    
      Logical unit number is already free.
     | 
  
  
    | 
      LIB$_LUNRESSYS
     | 
    
      Logical unit number reserved to system. This occurs if the specified 
      logical unit number is outside the range of 100 through 299.
     |