| Previous | Contents | Index |
BASEstar Classic physical points may be grouped together into pollsets to optimize data collection and to provide the ability to read a group of points on a specified time interval.
DCM allows you to read groups of physical points (variables) using the scattered pollset feature. Any combination of physical points may be included in a pollset. The use of the /SCATTERED qualifier is mandatory when creating the pollset.
Figure 3-2 shows an example of creating a scattered pollset for reading groups of named variables.
Figure 3-2 Scattered Pollset Definition
DCM> create pollset POLL1/device=TEST_PLC/interval=15/scattered
DCM> create phypoint P1/dev=TEST_PLC/format=long/addr=VMD_INT32 -
_DCM> /poll=POLL1/COLLECT
DCM> create phypoint P2/dev=TEST_PLC/format=word/addr=OSAPWORD -
_DCM> /poll=POLL1/COLLECT
DCM> SHOW POLL */DEV=TEST_PLC/FUL
Device Name : TEST_PLC
Pollset Name: POLL1
Interval : 15
Enabled : No
Format : SCATTERED
Start Address : VMD_INT32
Number elements : 2
IO blocks : 1
Size (in bytes) : 6
Buffers not dist: 0
Defined on ....
Definition last updated on ....
Permanent Lka Ctr :0 Temporary Lka Ctr :0
Permanent Late Ctr :0 Temporary Late Ctr :0
Permanent Device Errors :0 Temporary Device errors :0
Permanent No Buffers errors :0 Temporary No Buffers errors :0
BASEstar Classic point name: DCM Phypoint name:
P1
P2
DCM>
|
This service provides the equivalent of calling the omni_group_variable service for each physical point (variable) in the pollset.
For more information on physical points, see the BASEstar Classic Command Line Interface User's Guide.