| Previous | Contents | Index |
Use SYS$STARTUP:NET$CONFIGURE to configure your OSI Transport Template for Siemens communications.
Be sure to configure the template as a NULL Internet transport template. |
Table 2-4 gives a list of recommended OSI transport template parameters. Table 2-5 gives a list of OSI transport parameters that may need to be modified for your intallation. These parameters are explained in detail in the DECnet Plus documentation. Some are inter-dependent so that modifying one parameter may require changing other ones also.
| Parameter | Recommended Value1 |
|---|---|
| Keepalive Time | 3 2 |
| Retransmit Threshold | 2 2 |
| CR Timeout | 5 |
| ER Timeout | 5 |
| Parameter | |
|---|---|
| Maximum Transport Connections | |
| Maximum Remote NSAPs |
Other timers in the transport template may need to be modified depending on your specific hardware and network configuration.
To modify transport template values place an NCL script in SYS$COMMON:[SYSMGR] and execute it from your system startup command file. Use the following syntax to execute an NCL script.
$RUN SYS$SYSTEM:NCL @SYS$MANAGER:CUSTOM_NCL_SCRIPT.NCL |
Example 2-1 shows an example OSI transport template configured for NULL Internet.
| Example 2-1 NULL Internet OSI Transport Template |
|---|
NCL>sho osi transport template h1net all
Node 0 OSI Transport Template h1net
at 1996-10-17-14:49:41.446-04:00Iinf
Identifiers
Name = h1net
Characteristics
Keepalive Time = 60
Retransmit Threshold = 8
Initial Retransmit Time = 5
CR Timeout = 30
ER Timeout = 30
Network Service = CLNS
Security = <Default value>
Classes =
{
4
}
Checksums = True
Maximum NSDU Size = 2048
Expedited Data = True
CONS Template = <Default value>
Use CLNS Error Reports = True
Acknowledgement Delay Time = 1
Local NSAP = <Default value>
CLNS Inactive Area Address =
{
49::FF-00
}
Inbound = True
Loopback = False
Send Implementation Id = True
Extended Format = True
Network Priority = 0
Send Preferred maximum TPDU size = True
Send Request Acknowledgement = True
RFC1006 Port Number = 102
|
Example 2-2 shows an example OSI transport definition.
| Example 2-2 OSI Transport |
|---|
NCL>sho osi transport all char
Node 0 OSI Transport
at 1996-10-17-14:57:47.388-04:00Iinf
Characteristics
Maximum Transport Connections = 200
Maximum Receive Buffers = 4000
Delay Weight = 5
Delay Factor = 4
Maximum Window = 20
Maximum Multiplexing = 4294967295
Disconnect Holdback = 0
Maximum Network Connections = 4294967295
ISO Version = 1
Version = V1.1.0
CONS Classes Supported =
{
0 ,
2 ,
4
}
CLNS Classes Supported =
{
4
}
Support MAP = False
Maximum Remote NSAPs = 201
NSAP Selector = 33
CONS Filters =
{
"OSI Transport"
}
Congestion Avoidance = False
CONS NSAP Addresses =
{
}
Maximum RFC1006 Connections = 4294967295
RFC1006 Listener Ports =
{
102
}
Out Of Order Cache Size = 10
|
Furthermore there is a similar set of parameters pre-defined for the Siemens CP-535 communications card. The parameters on the host must match the pre-defined parameters on the Siemens CP-535. Setting the parameters at the recommended values will allow normal communications with the Siemens programmable controller. It is possible to choose other values for these parameters depending on your special network requirements. However, please consult DECnet Plus documentation carefully before changing any of these parameters.
| Previous | Next | Contents | Index |