The purpose of a copy operation is to duplicate data on a source disk to a target disk. At the end of a copy operation, both disks contain identical information, and the target disk becomes a complete member of the shadow set. Read and write access to the shadow set continues while a disk or disks are undergoing a copy operation.
The DCL command MOUNT initiates a copy operation when a disk is added to an existing shadow set. A copy operation is simple in nature: A source disk is read and the data is written to the target disk. This is usually done in multiple block increments referred to as LBN ranges. In an OpenVMS Cluster environment, all systems that have the shadow set mounted know about the target disk and include it as part of the shadow set. However, only one of the OpenVMS systems actually manages the copy operation.
Two complexities characterize the copy operation:
Volume Shadowing for OpenVMS handles these situations differently depending on the operating system version number and the hardware configuration. For systems running software earlier than OpenVMS Version 5.5--2, the copy operation is performed by an OpenVMS node and is known as an unassisted copy operation (see Section 6.2.1).
With Version 5.5--2 and later, the copy operation includes enhancements for shadow set members that are configured on controllers that implement new copy capabilities. These enhancements enable the controllers to perform the copy operation and are referred to as assisted copies (see Section 6.2.2).
Volume Shadowing for OpenVMS supports both assisted and unassisted
shadow sets in the same cluster. Whenever you create a shadow set, add
members to an existing shadow set, or boot a system, the shadowing
software reevaluate's each device in the changed configuration to
determine whether the device is capable of supporting the copy assist.
6.2.1 Unassisted Copy Operations
Unassisted copy operations are performed by an OpenVMS system. The actual transfer of data from the source member to the target is done through host node memory. Although unassisted copy operations are not CPU intensive, they are I/O intensive and consume a small amount of CPU bandwidth on the node that is managing the copy. An unassisted copy operation also consumes interconnect bandwidth.
On the system that manages the copy operation, user and copy I/Os compete evenly for the available I/O bandwidth. For other nodes in the cluster, user I/Os proceed normally and contend for resources in the controller with all the other nodes. Note that the copy operation may take longer as the user I/O load increases.
The volume shadowing software performs an unassisted copy operation when it is not possible to use the assisted copy feature (see Section 6.2.2). The most common cause of an unassisted copy operation is when the source and target disk or disks are not on line to the same controller subsystem. For unassisted copy operations, two disks can be active targets of an unassisted copy operation simultaneously, if the members are added to the shadow set on the same command line. Disks participating in an unassisted copy operation may be on line to any controller anywhere in a cluster.
During any copy operation, a logical barrier is created that moves across the disk, separating the copied and uncopied LBN areas. This barrier is known as a copy fence. The node that is managing the copy operation knows the precise location of the fence and periodically notifies the other nodes in the cluster of the fence location. Thus, if the node performing the copy operation shuts down, another node can continue the operation without restarting at the beginning.
Read I/O requests to either side of the copy fence are serviced only from a source shadow set member.
Write I/O requests before or at the fence are issued in parallel to all members of the shadow set.
Write I/O requests, after the fence, are completed first to source members, then to copy target members.
The time and amount of I/O required to complete an unassisted copy
operation depends heavily on the similarities of the data on the source
and target disks. It can take at least two and a half times longer to
copy a member containing dissimilar data than it does to complete a
copy operation on a member containing similar data.
6.2.2 Assisted Copy Operations
Unlike an unassisted copy, an assisted copy does not transfer data through the host node memory. The actual transfer of data is performed within the controller, by direct disk-to-disk data transfers, without having the data pass through host node memory. Thus, the assisted copy decreases the impact on the system, the I/O bandwidth consumption, and the time required for copy operations.
Shadow set members must be accessed from the same controller in order to take advantage of the assisted copy. The shadowing software controls the copy operation by using special MSCP copy commands, called disk copy data (DCD) commands, to instruct the controller to copy specific ranges of LBNs. For an assisted copy, only one disk can be an active target for a copy at a time.
For OpenVMS Cluster configurations, the node that is managing the copy operation issues an MSCP DCD command to the controller for each LBN range. The controller then performs the disk-to-disk copy, thus avoiding consumption of interconnect bandwidth.
By default, the Volume Shadowing for OpenVMS software (beginning with OpenVMS Version 5.5--2) and the controller automatically enable the copy assist if the source and target disks are accessed through the same HSC or HSJ controller.
Shadowing automatically disables the copy assist if:
See Section 6.4 for information about disabling and reenabling the
assisted copy capability.
6.3 Merge Operations
The purpose of a merge operation is to compare data on shadow set members and to ensure that inconsistencies are resolved. A merge operation is initiated if either of the following events occurs:
The merge operation is managed by one of the OpenVMS systems that has the shadow set mounted. The members of a shadow set are physically compared to each other to ensure that they contain the same data. This is done by performing a block-by-block comparison of the entire volume. As the merge proceeds, any blocks that are different are made the same --either both old or new---by means of a copy operation. Because the shadowing software does not know which member contains newer data, any full member can be the source member of the merge operation.
The shadowing software always selects one member as a logical master for any merge operation, across the OpenVMS Cluster. Any difference in data is resolved by a propagation of the information from the merge master to all the other members.
The system responsible for doing the merge operation on a given shadow set, updates the merge fence for this shadow set after a range of LBNs is reconciled. This fence "proceeds" across the disk and separates the merged and unmerged portions of the shadow set.
Application read I/O requests to the merged side of the fence can be satisfied by any source member of the shadow set. Application read I/O requests to the unmerged side of the fence are also satisfied by any source member of the shadow set; however, any potential data differences---discovered by doing a data compare operation---are corrected on all members of the shadow set before returning the data to the user or application that requested it.
This method of dynamic correction of data inconsistencies during read requests allows a shadow set member to fail at any point during the merge operation without impacting data availability.
Volume Shadowing for OpenVMS supports both assisted and unassisted
merge operations in the same cluster. Whenever you create a shadow set,
add members to an existing shadow set, or boot a system, the shadowing
software reevaluates each device in the changed configuration to
determine whether it is capable of supporting the merge assist.
6.3.1 Unassisted Merge Operations
For systems running software earlier than OpenVMS Version 5.5--2, the merge operation is performed by the system and is known as an unassisted merge operation.
To ensure minimal impact on user I/O requests, volume shadowing implements a mechanism that causes the merge operation to give priority to user and application I/O requests.
The shadow server process performs merge operations as a background process, ensuring that when failures occur, they minimally impact user I/O. A side effect of this is that unassisted merge operations can often take an extended period of time to complete, depending on user I/O rates. Also, if another node fails before a merge completes, the current merge is abandoned and a new one is initiated from the beginning.
Note that data availability and integrity are fully preserved during
merge operations regardless of their duration. All shadow set members
contain equally valid data.
6.3.2 Assisted Merge Operations
Starting with OpenVMS Version 5.5--2, the merge operation includes enhancements for shadow set members that are configured on controllers that implement assisted merge capabilities. The assisted merge operation is also referred to as a minimerge. The minimerge feature significantly reduces the amount of time needed to perform merge operations. Usually, the minimerge completes in a few minutes.
By using information about write operations that were logged in controller memory, the minimerge is able to merge only those areas of the shadow set where write activity was known to have been in progress. This avoids the need for the total read and compare scans required by unassisted merge operations, thus reducing consumption of system I/O resources.
Controller-based write logs contain information about exactly which LBNs in the shadow set had write I/O requests outstanding (from a failed node). The node that performs the assisted merge operation uses the write logs to merge those LBNs that may be inconsistent across the shadow set. No controller-based write logs are maintained for a one member shadow set. No controller-based write logs are maintained if only one OpenVMS system has the shadow set mounted.
The shadowing software does not automatically enable a minimerge on a system disk because of the requirement to consolidate crash dump files on a nonsystem disk. Dump off system disk (DOSD) is supported on both OpenVMS VAX and OpenVMS Alpha, starting with OpenVMS VAX Version 6.2 and OpenVMS Alpha Version 7.1. If DOSD is enabled, the system disk can be minimerged. |
The minimerge operation is enabled on nodes running OpenVMS Version 5.5--2 or later. Volume shadowing automatically enables the minimerge if the controllers involved in accessing the physical members of the shadow set support it. See the Volume Shadowing for OpenVMS Software Product Description (SPD 27.29.xx) for a list of supported controllers. Note that minimerge operations are possible even when shadow set members are connected to different controllers. This is because write log entries are maintained on a per controller basis for each shadow set member.
Volume Shadowing for OpenVMS automatically disables minimerges if:
The following transient conditions can also cause a minimerge operation to be disabled:
This section describes how to control assisted copy and minimerge operations on an HSC controller. It is not possible to control these operations on an HSJ controller.
To disable both the merge and copy performance assists on the HSC controller, follow these steps on each HSC controller for which you want to disable the assists:
HSC> RUN SETSHO SETSHO> SET SERVER DISK/NOHOST_BASED_SHADOWING SETSHO-I Your settings require an IMMEDIATE reboot on exit. SETSHO> EXIT SETSHO-Q Rebooting HSC. Press RETURN to continue, CTRL/Y to abort: |
After you issue these commands, the HSC controller automatically reboots:
INIPIO-I Booting... |
To reenable the assists, follow the same procedure on your HSC controller, but use the /HOST_BASED_SHADOWING qualifier on the SET SERVER DISK command.
Use the HSC command SHOW ALL to see whether the assists are enabled or disabled. The following example shows a portion of the SHOW ALL display that indicates the shadowing assists status:
HSC> SHOW ALL . . . 5-Jun-1997 16:42:51.40 Boot: 21-Feb-1997 13:07:19.47 Up: 2490:26 Version: V860 System ID: %X000011708247 Name: HSJNOT Front Panel: Secure HSC Type: HSC90 . . . Disk Server Options: Disk Caching: Disabled Host Based Shadowing Assists: Enabled Variant Protocol: Enabled Disk Drive Controller Timeout: 2 seconds Maximum Sectors per Track: 74 sectors Disk Copy Data connection limit: 4 Active: 0 . . . |
When a system, controller, or disk failure occurs, the shadowing software maintains data availability by performing the appropriate copy, merge, or minimerge operation. The following subsections describe the courses of action taken when failures occur. The course of action taken depends on the event and whether the shadow set is in a steady state or a transient state.
When a shadow set is in a steady state, the following transitions can occur:
Once the transition completes, the disks contain identical information and the shadow set returns to a steady state.
Transitions During Copy Operations
The following list describes the transitions that can occur to a shadow set that is undergoing a copy operation:
When a node failure occurs during a shadow set copy operation, merge behavior depends on whether or not the shadowing performance assists are enabled.
Transitions During Minimerge Operations
When a shadow set is undergoing a minimerge operation, the following transitions can occur:
Transitions During Merge Operations
The following list describes the transitions that can occur to the shadow set that is undergoing a merge operation when performance assists are not available: