6.3 HSx Failover Modes

The HSZ70, HSZ80, and HSG80 implement two modes of failover operation when they are in a dual-redundant configuration, transparent failover mode and multibus failover mode.

Note

OpenVMS requires that the HSG60 or HSG80 be in multibus failover mode. OpenVMS does not support transparent mode for the HSG60 or HSG80.

For the system to operate correctly, the HSx failover mode must be compatible with the configuration of the interconnect hardware and the host operating system software, as described in the following sections.

6.3.1 Transparent Failover Mode

In transparent failover mode, the HSZ presents each logical unit on one port of the dual controller pair. Different logical units may be assigned to different ports, but an individual logical unit is accessible through one port at a time. When the HSZ detects that a controller module has failed, it moves the logical unit to the corresponding port on the surviving controller, as shown in Figure 6-4.

Figure 6-4 Storage Subsystem in Transparent Mode


The assumption in transparent mode is that the two ports are on the same host bus, so the logical unit can move from one port to the other without requiring any changes to the host's view of the device. The system manager must ensure that the bus configuration is correct for this mode of failover. Transparent failover has been supported by OpenVMS since Version 6.2.

To select transparent failover mode, enter one of the following commands at the HSZ console, depending on your configuration:


HSZ> SET FAILOVER COPY=THIS_CONTROLLER 

or


HSZ> SET FAILOVER COPY=OTHER_CONTROLLER 

An example of the output of a console SHOW command on an HSZ in transparent mode follows:


z70_A => SHOW THIS_CONTROLLER 
Controller: 
        HSZ70 ZG64100160 Firmware XB32-0, Hardware CX25 
        Configured for dual-redundancy with ZG64100136 
            In dual-redundant configuration 
        Device Port SCSI address 7 
        Time: 02-DEC-1998 09:22:09 
Host port: 
        SCSI target(s) (0, 2, 3, 4, 5, 6) 
        Preferred target(s) (3, 5) 
        TRANSFER_RATE_REQUESTED = 20MHZ 
        Host Functionality Mode = A 
        Allocation class           0 
        Command Console LUN is target 0, lun 1 
Cache: 
        32 megabyte write cache, version 4 
        Cache is GOOD 
        Battery is GOOD 
        No unflushed data in cache 
        CACHE_FLUSH_TIMER = DEFAULT (10 seconds) 
        NOCACHE_UPS 

6.3.2 Multibus Failover Mode

In multibus failover mode, the HSx responds to SCSI Inquiry commands from the host on all ports of the dual controller pair. This allows the host to be aware of all the possible paths to the device. There are two advantages to having the host aware of all the paths to a device:

Note that, although the logical unit is visible on all ports, it is on line and thus capable of doing I/O on the ports of only one controller at a time. Different logical units may be on line to different controllers, but an individual logical unit is on line to only one controller at a time, as shown in Figure 6-5.

Figure 6-5 Storage Subsystem in Multibus Mode


You can determine which controller a logical unit is on line to by entering the HSx console command, as follows:


z70_A => SHOW UNIT FULL 
    LUN                                      Uses 
-------------------------------------------------------------- 
  D200                                       DISK20300 
        Switches: 
          RUN                    NOWRITE_PROTECT        READ_CACHE 
          MAXIMUM_CACHED_TRANSFER_SIZE = 32 
          ACCESS_ID = ALL 
        State: 
          ONLINE to the other controller 
          PREFERRED_PATH = OTHER_CONTROLLER 
        Size: 2050860 blocks 

The host executes I/O to a logical unit on one path at a time, until that path fails. If a controller has two ports, as the HSZ80 and the HSG80 controllers do, then different hosts can access the same logical unit over different ports of the controller to which the logical unit is online.

An HSx in multibus failover mode can only be used with the multipath functionality introduced in OpenVMS Version 7.2.

To select multibus failover mode, enter one of the following commands at the HSx: console, whichever is appropriate to your configuration:


HSZ> SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER 

or


HSZ> SET MULTIBUS_FAILOVER COPY=OTHER_CONTROLLER 

An example of the output of a console SHOW command on an HSx controller in multibus mode follows:


z70_B => SHOW THIS_CONTROLLER 
Controller: 
        HSZ70 ZG64100136 Firmware XB32-0, Hardware CX25 
        Configured for MULTIBUS_FAILOVER with ZG64100160 
            In dual-redundant configuration 
        Device Port SCSI address 6 
        Time: NOT SET 
Host port: 
        SCSI target(s) (0, 2, 3, 4, 5, 6) 
 
        TRANSFER_RATE_REQUESTED = 20MHZ 
        Host Functionality Mode = A 
        Allocation class           0 
        Command Console LUN is target 0, lun 1 
Cache: 
        32 megabyte write cache, version 4 
        Cache is GOOD 
        Battery is GOOD 
        No unflushed data in cache 
        CACHE_FLUSH_TIMER = DEFAULT (10 seconds) 
        NOCACHE_UPS 

6.3.3 Port Addressing for Controllers in Multibus Mode

There is a difference between parallel SCSI and FC in the way that the ports on multibus controllers are addressed. In parallel SCSI (the HSZ70 and the HSZ80), all the ports are assigned the same SCSI target IDs. This is noted for the HSZ80 configuration shown in Figure 6-6.

Figure 6-6 Port Addressing for Parallel SCSI Controllers in Multibus Mode


The reason all the ports have the same target ID is that the target ID is part of the OpenVMS device name (for example, the 6 in $4$DKC600), and the device name must be the same for all paths. This means that each port must be on a separate SCSI bus or there will be an address conflict.

In Fibre Channel configurations with the HSG80, all the ports have their own FC address and WWID, as noted in Figure 6-7.

Figure 6-7 Port Addressing for Fibre Channel Controllers in Multibus Mode


The ports on the HSG80 have separate FC addresses and WWIDs because these items are not used in the OpenVMS FC device name. This means that any number of ports can be connected to the same FC interconnect. In fact, all the ports of the HSG80 in multibus mode should be connected, even if there is just one interconnect, because this can improve availability and performance.

6.4 Parallel SCSI Multipath Configurations

The figures in this section show systems configured for transparent failover and for multipath failover. The special considerations for controller modules that have multiple ports, such as the HSZ80, are also described.

6.4.1 Transparent Failover

Transparent failover in a parallel SCSI configuration, as shown in Figure 6-8, requires that both controller modules be on the same SCSI bus.

Figure 6-8 Parallel SCSI Configuration With Transparent Failover


In this configuration:

6.4.2 Multibus Failover and Multiple Paths

A parallel SCSI configuration with multiple paths from the host to storage offers higher availability and performance than a configuration using transparent failover. Figure 6-9 shows this configuration.

Figure 6-9 Parallel SCSI Configuration With Multibus Failover and Multiple Paths


Note the following about this configuration:

6.4.3 Configurations Using Multiported Storage Controllers

Higher levels of availability and performance can be achieved with the use of multiported storage controllers, such as the HSZ80. The HSZ80 storage controller is similar to the HSZ70 except that each HSZ80 controller has two ports.

This section shows three configurations that use multiported storage controllers. The configurations are presented in order of increasing availability.

Figure 6-10 shows a single host with a single interconnect, using an HSZ80 in transparent mode.

Figure 6-10 Multiported Parallel SCSI Configuration With Single Interconnect in Transparent Mode


Note the following about this configuration:

Figure 6-11 shows a system configured in transparent mode using two paths from the host.

Figure 6-11 Multiported Parallel SCSI Configuration With Multiple Paths in Transparent Mode


In this configuration:

Note that in this configuration, although there are two buses, there is only one path from the host to a particular logical unit. When a controller fails, the logical unit moves to the corresponding port on the other controller. Both ports are on the same host bus.

This configuration has better performance than the one in Figure 6-10 because both SCSI buses can be simultaneously active. This configuration does not have higher availability, however, because there is still only one path from the host to the logical unit.

Figure 6-12 shows a system using the multiported HSZ80 storage controller configured in multibus mode.

Figure 6-12 Multiported Parallel SCSI Configuration With Multiple Paths in Multibus Mode


In this configuration:

6.5 Device Naming for Parallel SCSI Multipath Configurations

SCSI device names have evolved as systems have become larger and more complex. At first, SCSI device names were entirely path dependent. The device name indicated the node, host adapter, SCSI bus ID, and logical unit number (LUN) used to access the device. Path-based names are not suitable for multiple host and multiple path environments because:

The first two of these issues were addressed by the use of the node allocation class and the port allocation class. The third issue requires the introduction of an HSZ controller-based allocation class. These three allocation classes are reviewed in the following sections.

6.5.1 Review of Node Allocation Classes

A node allocation class is used in a device name in place of a node name. A node allocation class is needed to produce a unique device name when multiple nodes have a direct connection to the same SCSI device.

A node allocation class can only be used in a device name when all nodes that share access to a SCSI storage device:

Figure 6-13 shows a configuration whose devices are named using a node allocation class.

Figure 6-13 Devices Named Using a Node Allocation Class


6.5.2 Review of Port Allocation Classes

A port allocation class in a device name designates the host adapter that is used to access the device. The port allocation class replaces the node allocation class in the device name, and the adapter controller letter is set to the constant A.

The port allocation class can be used when SCSI systems need more SCSI IDs to produce unique device names, or when the controller letter of the adapters on a shared bus do not match. A port allocation class can only be used in a device name when all nodes that share access to a SCSI storage device have only one direct path to the device.

Figure 6-14 shows a configuration whose devices are named using a port allocation class.

Figure 6-14 Devices Named Using a Port Allocation Class


6.5.3 Device Naming Using HSZ Allocation Classes

When any node has multiple buses connecting to the same storage device, the new HSZ allocation class shown in Figure 6-15 must be used.

Figure 6-15 Devices Named Using an HSZ Allocation Class


An HSZ allocation class is similar to the HSC, HSD, and HSJ allocation classes. The device name, using an HSZ allocation class number, takes the following form:


$HSZ-allocation-class$ddcu

where:

The system manager sets an HSZ allocation class from the HSZ console, using one of the following commands, as appropriate to the configuration:


HSZ> SET THIS_CONTROLLER ALLOCATION_CLASS = n

or


HSZ> SET OTHER_CONTROLLER ALLOCATION_CLASS = n

where n is a value from 1 to 999.

When the allocation class is set on one controller module in a dual redundant configuration, it is automatically set to the same value on the other controller.

In the following example, the allocation class is set to 199. The example shows that the value is set for both controllers.


z70_B => SET THIS ALLOCATION_CLASS=199 
z70_B => SHOW THIS_CONTROLLER 
Controller: 
        HSZ70 ZG64100136 Firmware XB32-0, Hardware CX25 
        Configured for MULTIBUS_FAILOVER with ZG64100160 
            In dual-redundant configuration 
        Device Port SCSI address 6 
        Time: NOT SET 
Host port: 
        SCSI target(s) (0, 2, 3, 4, 5, 6) 
 
        TRANSFER_RATE_REQUESTED = 20MHZ 
        Host Functionality Mode = A 
        Allocation class         199 
        Command Console LUN is target 0, lun 1 
Cache: 
        32 megabyte write cache, version 4 
        Cache is GOOD 
        Battery is GOOD 
        No unflushed data in cache 
        CACHE_FLUSH_TIMER = DEFAULT (10 seconds) 
        NOCACHE_UPS 
z70_B => SHOW OTHER_CONTROLLER 
Controller: 
        HSZ70 ZG64100160 Firmware XB32-0, Hardware CX25 
        Configured for MULTIBUS_FAILOVER with ZG64100136 
            In dual-redundant configuration 
        Device Port SCSI address 7 
        Time: NOT SET 
Host port: 
        SCSI target(s) (0, 2, 3, 4, 5, 6) 
 
        TRANSFER_RATE_REQUESTED = 20MHZ 
        Host Functionality Mode = A 
        Allocation class         199 
        Command Console LUN is target 0, lun 1 
Cache: 
        32 megabyte write cache, version 4 
        Cache is GOOD 
        Battery is GOOD 
        No unflushed data in cache 
        CACHE_FLUSH_TIMER = DEFAULT (10 seconds) 
        NOCACHE_UPS 

The following rules pertain to the use of an HSZ allocation class in SCSI device names:

  1. In multibus mode, an HSZ allocation class must be used in a device name (otherwise, the device is not configured).
  2. In transparent mode, an HSZ allocation class can be used in a device name but it is not required.
  3. The HSZ allocation class number must be the same for both controllers of an HSZ. This is handled automatically by the HSZ firmware.
  4. The HSZ allocation class number must be unique among all types of allocation classes throughout the cluster.
  5. The HSZ allocation class must be specified when referring to devices that have an HSZ allocation class. For example, the names DKA500 and NODE10$DKA500 can not be used. In addition, the $GETDVI system service will only return the fully specified name, including the HSZ allocation class, for these devices.

6.6 Fibre Channel Multipath Configurations

Figure 6-16 shows a multipath configuration with the storage controllers configured in multibus mode.

Figure 6-16 Single Host With Two Dual-Ported Storage Controllers and Two Buses


Note the following about this configuration:

Note that each HSG80 port has its own Fibre Channel address and Fibre Channel port WWID. This is different from an HSZ80 in multibus mode where all the ports respond to the same SCSI address and must, therefore, be connected to different SCSI buses. The separate FC addresses enable both ports of the dual HSG80 to be on the same FC.

Figure 6-17 shows another multipath configuration with its storage controllers configured in multibus mode.

Figure 6-17 Single Host With Two Dual-Ported Storage Controllers and Four Buses


Note the following about this configuration:

6.7 Implementing Multipath Configurations

Parallel SCSI and Fibre Channel interconnects support multipath configurations. Implementation of these configurations is similar, and the system parameters and the command for specifying paths are the same. The syntax for the path identifiers differs.

Implementing multiple paths to devices consists of the following steps:

  1. Configuring a system or systems with multiple physical paths to those devices for which you want multipath support
  2. Setting the HSx controller to multibus mode
  3. Optionally qualifying multipath support by setting certain multipath system and console parameters, as appropriate for your configuration
  4. Optionally tailoring the operation of multipath functionality, using the DCL command SET DEVICE/qualifier/PATH=path-identifier

6.7.1 Valid Multipath Configurations

Figure 6-18 shows a valid multipath, multihost configuration.

Figure 6-18 Two Hosts With Shared Buses and Shared Storage Controllers


Note the following about this configuration:

This configuration provides each host with two direct paths and one MSCP served path to each device.

Figure 6-19 shows a valid multipath configuration for systems that are not configured on the same bus.

Figure 6-19 Two Hosts With Shared, Multiported Storage Controllers


Note the following about this configuration:

This configuration provides each host with two direct paths, one to each storage controller, and one MSCP served path to each device.