BASEstartm Open DAS
for Allen-Bradley Data Highwaytm
on OpenVMStm
Installation and User's Guide


Previous Contents Index

Figure 3-32 shows the structure of a legal I/O data table address for the PLC-5/250.

Table 3-20 shows examples of legal I/O data table addresses for the PLC-5/250.

Figure 3-32 PLC-5 / 250 I/O Address Format


Table 3-20 Example PLC-5 / 250 I/O Addresses
Example Address MMS Type1 Description
I:20 UNSIGNED_16 Input image rack 2 group 0 octal
I:277 INTEGER_16 Input image rack 27 group 7 octal
I:177/17 BIT_STRING Bit 17 of rack 17 group 7 octal
$O:77/1 BIT_STRING Bit 1 of rack 7 group 7 octal
I:0 Array of 10 UNSIGNED_16 Ten words beginning at rack 0 group 0


1Arrays are supported. Structures are not supported. Variable size arrays are not supported.


Previous Next Contents Index