Updated:
11 December 1998
|
OpenVMS System Messages: Companion Guide for Help
Message Users
Datagram Free Queue Insert Failure
Facility: Cluster Port Driver
Explanation: The port driver attempts to reinitialize
the port; after 50 failed attempts, it marks the device off line. This
error is caused by a failure to obtain access to an interlocked queue.
Possible sources of the problem are CI hardware failures or memory, SBI
(VAX-11/780), CMI (VAX-11/750), BI, PCI, or XMI contention.
User Action: Contact a DIGITAL support representative.
Datagram Free Queue Remove Failure
Facility: Cluster Port Driver
Explanation: The port driver attempts to reinitialize
the port; after 50 failed attempts, it marks the device off line. This
error is caused by a failure to obtain access to an interlocked queue.
Possible sources of the problem are CI hardware failures or memory, SBI
(VAX-11/780), CMI (VAX-11/750), BI, PCI, or XMI contention.
User Action: Contact a DIGITAL support representative.
DBLERR, double error halt restart
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable hardware error. Because of the severity of the error,
further operation is impossible or it could corrupt user data. After
all physical memory is written to a system dump file, the system
automatically reboots if the BUGREBOOT system parameter is set to 1.
User Action: Thoroughly test all system hardware
components. If no hardware errors are located and if the problem
persists, note the conditions at the time of the error. Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DEADLOCK, deadlock detected
Facility: MOUNT, Mount Utility
Explanation: The first 12 characters of an ISO 9660
CD-ROM's volume name and volume set name are the same. When an attempt
is made to mount the volume, both names are used to construct an
OpenVMS lock request to manage volumes within a volume set. However, if
the first 12 characters of the names match, the lock request fails.
User Action: Mount the volume specifying a different
volume set name.
DECPTREF, decrement page table reference count error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DEFCLI, you are not authorized to specify CLI parameters
Facility: LOGIN, Login Procedure
Explanation: Authorization is needed to specify an
alternate command language interpreter (CLI) or alternate CLI tables.
User Action: Log in again without specifying the /CLI
or /TABLES qualifiers after your user name.
DELCONPFN, fatal error in delete contents of PFN
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DELETE, error deleting 'file-name' file ID ('numeric-string')
Facility: BACKUP, Backup Utility
Explanation: An error is encountered during an attempt
to delete the file with the specified file identification in response
to the /DELETE qualifier. The accompanying message provides additional
information.
User Action: None.
DELETESWL, 'device-name' is write protected - file deletion pass not
executed
Facility: BACKUP, Backup Utility
Explanation: The input device is software write
locked. The Backup utility cannot perform the file deletion pass.
User Action: Dismount the input device, remount it
writable, and either delete the files by hand or reenter the BACKUP
command.
DELGBLSEC, delete global section error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DELGBLWCB, delete global section window error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DELPORT, deleted port 'port-name'
Facility: LAT, LAT Facility
Explanation: The specified port has been deleted by
LATCP.
User Action: None.
DELSERVICE, deleted service 'service-name'
Facility: LAT, LAT Facility
Explanation: The specified service has been deleted by
LATCP.
User Action: None.
DELWSLEX, delete working set list entry index error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DENIGNORED, /DENSITY qualifier not appropriate to this device; ignored
Facility: MOUNT, Mount Utility
Explanation: The /DENSITY qualifier was supplied on
the command line for a device that does not support various densities.
The qualifier is ignored.
User Action: Omit the /DENSITY qualifier to avoid
getting this system message. Use the /MEDIA_FORMAT=[NO]COMPACTION
qualifier if the device supports compaction.
DENSITY, 'saveset-spec' does not support specified density - default
used
Facility: BACKUP, Backup Utility
Explanation: The specified tape hardware does not
support the density selected by the /DENSITY qualifier. The Backup
utility uses the default density.
User Action: Use a different tape device, or specify a
different density.
DEQSUBLCKS, tried to dequeue lock with sublocks
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DETSHADINCON, mount has detected an inconsistent state for shadowing
Facility: MOUNT, Mount Utility
Explanation: MOUNT has detected an internal
inconsistency while attempting to mount a shadow set. This message
indicates a failure in either MOUNT or the OpenVMS Volume Shadowing
software.
User Action: Contact a DIGITAL support representative and provide as much
detail as possible about the circumstances surrounding this error.
DEVBUSY, mount or dismount in progress on device
Facility: MOUNT, Mount Utility
Explanation: A mount or dismount operation is
currently in progress on the device, possibly on another node in the
cluster. If the condition persists, the other mount may be waiting for
an operator request to complete, or the device may be malfunctioning.
User Action: Determine where the mount or dismount is
in progress and rectify the problem that is holding it up.
DEVCOUNT, number of devices must match number of volumes
Facility: MOUNT, Mount Utility
Explanation: The number of devices specified in the
DCL command MOUNT to mount a disk volume set does not match the number
of volume labels specified in the command.
User Action: Verify the names of the devices and
volume labels for the command and then reenter the command with a
matching number of devices and volume labels.
DEVDMT, device is marked for dismount
Facility: MOUNT, Mount Utility
Explanation: The device is in the process of being
dismounted. No mount requests can be processed on this device until the
dismount completes. If this condition persists, files are open on the
device.
User Action: Close any open files on the device. If
other processes have open files, the system manager may need to resolve
the situation.
DEVICES, only one device allowed
Facility: MOUNT, Mount Utility
Explanation: More than one device was specified in the
DCL command MOUNT. Only one volume at a time can be mounted for this
specified type of mount.
User Action: Reenter the DCL command MOUNT, specifying
only one device.
DEVNOFE, device does not support FORCED ERROR handling. To override use
the /OVERRIDE=NO_FORCED_ERROR qualifier
Facility: MOUNT, Mount Utility
Explanation: The device being mounted into a shadow
set does not support forced error handling and the
/OVERRIDE=NO_FORCED_ERROR qualifier was not specified.
User Action: Specify the /OVERRIDE=NO_FORCED_ERROR
qualifier and retry the operation.
DEVNOTKNWN, device not known: 'input'
Facility: SYSGEN, System Generation Utility
Explanation: The specific device is unknown.
User Action: See the OpenVMS VAX Device Support Manual for the correct
UNIBUS controller name.
DEVSHAMEM, device is already mounted as a shadow set member
Facility: MOUNT, Mount Utility
Explanation: The device you attempted to mount as a
nonshadowed device is already mounted elsewhere in the cluster as a
shadow set member.
User Action: Mount the device as a member of a shadow
set. You can use DSA: to specify a generic virtual unit if you do not
know which virtual unit contains the device.
DIAGPACK, 'disk' is a diagnostic pack
Facility: BACKUP, Backup Utility
Explanation: Either a Backup utility operation
attempted to use a volume identified as a diagnostic volume, or the
INITIALIZE command was used to initialize a diagnostic volume. In
either case, the volume cannot be used.
User Action: Retry the operation using another volume.
DIFVOLMNT, different volume already mounted on this device
Facility: MOUNT, Mount Utility
Explanation: Previously, a different volume was
mounted on this device on another node in the cluster. The device may
be in mount verification on the other node. Either the original volume
was removed from the device and replaced with another, or its volume
identification was overwritten.
User Action: Restore the previously mounted volume to
the device. If this is not possible, dismount the device on all nodes
that currently have it mounted. Then retry the mount operation.
DIRENTRY, ACP failed to find same directory entry
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DISKCLASS, fatal error detected by Disk Class driver (DUDRIVER)
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DISKFRAG, free space on 'device-name' is too fragmented
Facility: BACKUP, Backup Utility
Explanation: The number of free extents on the
specified volume is unreasonably large. The volume cannot be used as a
save-set disk.
User Action: Reinitialize the volume, or select
another volume and retry the operation.
DISMAL, all of the volumes have been dismounted
Facility: MOUNT, Mount Utility
Explanation: All of the volumes mounted by this
invocation of $MOUNT or the MOUNT command have been dismounted because
of errors that were detected after the volumes were mounted.
User Action: Take the action based on the preceding
messages, and reenter the MOUNT command.
DISMOUNTD, volume 'volume-name' of volume-set 'volume-set-name'
dismounted
Facility: MOUNT, Mount Utility
Explanation: The specified volume of the specified
volume set has been dismounted because of errors encountered in
processing the volume after it is mounted. An error with part of a
volume set causes the entire volume set to be dismounted. This message
appears for each member of the volume set that is dismounted due to the
error condition. Only those volumes that were mounted by this
invocation of the MOUNT command are listed. If the volume set name is
not available, the string "name n/a" appears as the name of
the volume set.
User Action: Take action based on the accompanying
message and reenter the MOUNT command.
DISMPART, some of the volumes have been dismounted
Facility: MOUNT, Mount Utility
Explanation: Some of the volumes that were mounted by
this invocation of the Mount utility or the MOUNT command have been
dismounted due to errors detected after the volumes were mounted.
User Action: Take action based on the preceding
messages, and reenter the MOUNT command.
DISRECONNECT, you are not authorized to do reconnections
Facility: LOGIN, Login Procedure
Explanation: Authorization is needed to reconnect to
disconnected processes.
User Action: Log in again without specifying the
/CONNECT qualifier after your user name.
DISUSER, account is disabled
Facility: LOGIN, Login Procedure
Explanation: An attempt is made to log in to an
account when the account is disabled. An account's system access can be
restricted by setting the DISUSER flag in the user authorization file.
This message is written to the system accounting and security audit
records; the NOTVALID message displays to the user.
User Action: None.
DOUBLDALOC, double deallocation of swap file space
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DOUBLDEALO, double deallocation of memory block
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a DIGITAL support representative and describe the conditions leading to the error.
DRIVENAM, driver name is 'driver-name'
Facility: SYSGEN, System Generation Utility
Explanation: This message is issued with the message
SYSVERDIF to identify the driver.
User Action: See the SYSGEN message SYSVERDIF for user
action information.
DRVERR, fatal drive error
Facility: MOUNT, Mount Utility
Explanation: In a SCSI OpenVMS Cluster environment, a
request has been made to mount a device on a shared SCSI bus and the
device does not support SCSI-2 tagged command queuing (TCQ).
User Action: If you want to mount a device on a shared
SCSI bus, the device must support TCQ.
DSSI Terminator Power failure, possible blown fuse.
Facility: Cluster Port Driver
Explanation: The adapter has detected a hardware
problem.
User Action: Check the terminator fuse. If it is
blown, replace it or contact a DIGITAL support representative to check the DSSI hardware.
DUALLOC, dual allocation on volume 'n'
Facility: RBLD, REBUILD Command (Mount Utility)
Explanation: A logical block on the specified relative
volume is allocated to more than one file.
User Action: Execute the DCL command
ANALYZE/DISK_STRUCTURE/NOREPAIR for the volume. This command invokes
the Analyze/Disk_Structure utility, which issues a message for each
case of dual file allocation. Each message identifies the file name,
the range of logical block numbers that are allocated, and the virtual
block numbers that map to the logical blocks.
After you determine the files involved in each case of dual allocation,
disallow any other file activity for them and copy all but one file to
a new version. Then delete the versions containing dual allocation.
This causes blocks that are not actually free to be marked as free
blocks in the storage bit map.
Finally, reexecute the ANALYZE/DISK_STRUCTURE/REPAIR command. Then
examine each file and reconstruct from backup media any files that have
been corrupted.
Dump aborted, page tables may be corrupted
Facility: BUGCHECK, System Bugcheck
Explanation: When writing a selective dump (SYSGEN
parameter DUMPSTYLE set to 1), the OpenVMS operating system relies
heavily on the integrity of the various system and process page tables.
This message indicates that the system might have detected corruption
in these page tables, and it will abort further dumping. You might not
be able to analyze the dump.
User Action: Contact a DIGITAL support representative.
DUPDEVSPC, duplicate device specified
Facility: MOUNT, Mount Utility
Explanation: The same tape device is specified more
than once in a list of tape devices for the DCL command MOUNT.
User Action: Reenter the MOUNT command, specifying
each device only once.
DUPLABEL, duplicate label 'label' not allowed with /EXACT_ORDER
qualifier
Facility: BACKUP, Backup Utility
Explanation: Duplicate labels cannot be specified with
the /EXACT_ORDER qualifier. The specified label matches a label that
was entered previously.
User Action: Reenter the command, specifying unique
labels.
DUPOPT, previously specified callable interface option type invalid,
argument position 'position', option type = 'option-type'
Facility: BACKUP, Backup Utility
Explanation: An option type is specified more than
once in the set of options. It is illegal to specify duplicates for
this option type.
User Action: Note the value of the option type found
and its relative position in the set of options specified to the BACKUP
API; then remove redundant specifications of this option type. (Refer
to the BACKUP documentation and the BACKUP API definitions files for
valid option values.)
DUPRVN, duplicate volume number already mounted
Facility: MOUNT, Mount Utility
Explanation: A volume of the same relative volume
number and the same volume set name is already mounted. An attempt is
being made to mount a volume that belongs to a volume set with the same
name as a volume set that is already mounted.
User Action: Make sure that the correct volume has
been mounted. Verify that the volume status (/SHARE, /NOSHARE, /GROUP,
or /SYSTEM) is defined consistently with volumes already mounted.
DUPVOLNAM, volume label already present in set
Facility: MOUNT, Mount Utility
Explanation: During an attempt to add a volume to an
existing volume set, the specified volume set is found to contain a
volume with the label specified.
User Action: Verify the labels on the existing volumes
in the set. Choose a new label for the volume you are adding to the
set, reinitialize the volume, and reenter the DCL command MOUNT/BIND.
DZRO_ISD, image contains demand zero sections
Facility: LOADER, Executive Image Loader
Explanation: A load request was made for an executive
image that illegally contains demand zero sections.
User Action: Correct the link procedure used to build
the executive image; specify the appropriate PSECT_ATTR and COLLECT
statements to eliminate the demand zero sections.