19.6.3 Displaying Information on Your Screen

Several parts of UETP, such as some device tests, UETINIT00.EXE, UETCLIG00.EXE, and UETDNET00.COM, let you obtain additional information concerning the progress of the test run or the problems the test encounters. Because this information is usually insignificant, it is not displayed on the screen.

To view the information, enter the following command to define the logical name MODE and run the program:


$ DEFINE MODE DUMP

19.6.4 Example Screen Display (VAX Only)

The following example shows the output for UETINIT00.EXE on a VAX 6000 computer, and logical name MODE defined as DUMP:


 
$DEFINE MODE DUMP 
$RUN UETINIT00 
 
       Welcome to VAX/VMS UETP Version X7.3 
 
%UETP-I-ABORTC, UETINIT00 to abort this test, type ^C 
 
You are running on a VAX 6000-430 CPU with 327680 pages of memory. 
The system was booted from _$11$DUA6:[SYS0.]. 
 
Run "ALL" UETP phases or a "SUBSET" [ALL]? 
How many passes of UETP do you wish to run [1]? 
 
The default number of loads is the minimum result of 
 
1) CPU_SCALE * ((MEM_FREE + MEM_MODIFY) / (WS_SIZE * PER_WS_INUSE)) 
        7.32 * ((  232390 +       5048) / (   1024 *         0.20))  = 8486 
 
2) Free process slots                                                = 296 
 
3) Free page file pages / Typical use of page file pages per process 
                1099992 /                                       1000 = 1099 
 
How many simulated user loads do you want [296]? 
Do you want Long or Short report format [Long]? 
 
UETP starting at  1-MAR-2001 16:00:43.86 with parameters: 
DEVICE LOAD DECNET CLUSTER  phases, 1 pass, 296 loads, long report. 
 
$ 

This program does not initiate any phase; it displays the equation used by UETP to determine user load and the specific factors that are employed in the current run.

Respond to the questions by pressing Return. After you respond to the first prompt, the program displays the expressions that determine the default number of simultaneous processes. The following definitions apply:

UETINIT00 also displays the specific values represented by the expressions. In this example, UETP selects 296 as the default for simulated user loads, because 296 is the minimum result of the three expressions.

Deassign the logical name MODE before running UETP, unless you prefer to see the user load breakdown every time you run UETP.

19.6.5 Example Screen Display (Alpha Only)

The following example shows the output for UETINIT00.EXE on an Alpha system, with logical name MODE defined as DUMP:


$ DEFINE MODE DUMP 
$ RUN UETINIT00 
 
       Welcome to OpenVMS Alpha UETP Version 7.3 
 
%UETP-I-ABORTC, UETINIT00 to abort this test, type ^C 
 
You are running on a AlphaServer 4100 5/533 4MB CPU. 
The system was booted from _$4$DKA300:[SYS0.]. 
 
Run "ALL" UETP phases or a "SUBSET" [ALL]? 
How many passes of UETP do you wish to run [1]? 
 
The default number of loads is the minimum result of 
 
1) (MEM_FREE + MEM_MODIFY) / ( WS_SIZE ) 
   ( 1807872 +      10496) / (  16512)                         = 110 
 
2) Free process slots                                          = 488 
 
3) Free page file pages / Typical use of blocks per process 
                 650240 /                               1000 = 650 
 
How many simulated user loads do you want [110]? 
Do you want Long or Short report format [Long]? 
 
UETP starting at  1-MAR-2001 15:53:19.52 with parameters: 
DEVICE LOAD DECNET CLUSTER  phases, 1 pass, 110 loads, long report. 

This program does not initiate any phase; it displays the equation used by UETP to determine user load and the specific factors that are employed in the current run.

Respond to the questions by pressing the Return key. After you respond to the first prompt, the program displays the expressions that determine the default number of simultaneous processes. The following definitions apply:

UETINIT00 also displays the specific values represented by the expressions. In this example, UETP selects 110 as the default for simulated user loads, because 100 is the minimum result of the three expressions.

Deassign the logical name MODE before running UETP, unless you prefer to see the user load breakdown every time you run UETP.

19.6.6 Defining a Remote Node for UETP Ethernet Testing

Occasionally during the UETUNAS00 test, it is difficult to determine whether the problem reports concern the device under test or the remote device. The easiest way to ensure proper error reporting is to define a good turnaround. A good turnaround is a remote node that you know turns around Ethernet packets correctly and is up and waiting in the ready state.

You can make the UETUNAS00 test use a known good turnaround by performing the following actions. In the commands that follow, assume that the good device is on node BETA and that node BETA is already defined in the network database.

  1. Find the address of the good Ethernet node by using the Network Control Program (NCP). To use NCP, the following conditions must apply:
    Enter the following commands and press Return:


    $ RUN SYS$SYSTEM:NCP
    NCP> TELL BETA SHOW EXECUTOR STATUS
    

    If node BETA has not been defined in your network database, NCP displays an error message. In this event, specify another good node and retry the command. Otherwise, see your system or network manager.
    NCP displays information similar to the following messages:


    Node Volatile Status as of  22-JUN-2000 16:13:02 
     
    Executor node = 19.007 (BETA) 
     
    State                    = on 
    Physical address         = AA-00-03-00-76-D3 
    Active links             = 6 
    Delay                    = 1 
    

  2. Use the displayed physical address (in this case, AA00030076D3) to define the logical name TESTNIADR to point to the good turnaround. Note that you do not specify the hyphens (-).
    First, log in to the SYSTEST account. Then enter the following command:


    $ DEFINE/SYSTEM TESTNIADR AA00030076D3
    

  3. Run UETP.
  4. When UETP has completed, deassign the logical name TESTNIADR by entering the following command:


    $ DEASSIGN/SYSTEM TESTNIADR
    

19.6.7 Log Files

UETP stores all information generated by all UETP tests and phases from its current run in one or more UETP.LOG files, and it stores the information from the previous run in one or more OLDUETP.LOG files. If a run of UETP involves multiple passes, there will be one UETP.LOG or one OLDUETP.LOG file for each pass.

At the beginning of a run, UETP deletes all OLDUETP.LOG files, and renames any UETP.LOG files to equivalent versions of OLDUETP.LOG. Then UETP creates a new UETP.LOG file and stores the information from the current pass in it. Subsequent passes of UETP create higher versions of UETP.LOG. Therefore, at the end of a run of UETP that involves multiple passes, there is one UETP.LOG file for each pass. In producing the files UETP.LOG and OLDUETP.LOG, UETP provides the output from the two most recent runs.

The cluster test creates a NETSERVER.LOG file in SYS$TEST for each pass on each system included in the run. If the test is unable to report errors (for example, if the connection to another node is lost), the NETSERVER.LOG file on that node contains the result of the test run on that node. UETP does not purge or delete NETSERVER.LOG files; therefore, you must delete them occasionally to recover disk space.

If a UETP run does not complete normally, SYS$TEST can contain other log files. Ordinarily these log files are concatenated and placed within UETP.LOG. You can use any log files that appear on the system disk for error checking, but you must delete these log files before you run any new tests. You can delete these log files yourself or rerun the entire UETP, which checks for old UETP.LOG files and deletes them.

19.7 Troubleshooting: Possible UETP Errors

This section is intended to help you identify and solve problems you can encounter running UETP. You should refer to this section if you need help understanding a system failure and isolating its cause. This section is not intended as a repair manual and is not expected to diagnose any flaws in your system. It should, however, help you to interpret and act upon the information in the error messages.

If you are unable to correct an error after following the steps in this section, you should contact a Compaq support representative. Any information you can supply about the measures you have taken to isolate the problem will help your a Compaq support representative diagnose the problem.

19.7.1 Summary of Common Failures

The following problems are the most common failures encountered while running UETP:

The sections that follow describe these errors and offer the best course of action for dealing with each one.

19.7.2 Wrong Quotas, Privileges, or Account

If your assigned quotas or privileges do not match standard quotas and privileges for the SYSTEST account, UETP displays the following error message:


********************** 
*  UETINIT00         * 
*  Error count =  1  * 
********************** 
-UETP-W-TEXT,   The following: 
 
        OPER privilege, 
        BIOLM  quota, 
        ENQLM  quota, 
        FILLM  quota, 
 
are nonstandard for the SYSTEST account and may result in UETP errors. 

This message informs you that the OPER privilege and the BIOLM, ENQLM, and FILLM quotas either are not assigned correctly or are not assigned at all.

Note

UETP displays a similar message if you run the cluster integration test phase and the privileges and quotas for the SYSTEST_CLIG account are incorrect. The SYSTEST and SYSTEST_CLIG accounts require the same privileges and quotas. Take the action described in this section for both accounts.

Solution

To correct the problem, use the following procedure:

  1. Display all privileges and quotas in effect for the SYSTEST account using the Authorize utility (AUTHORIZE) as follows:


    $ SET DEFAULT SYS$SYSTEM
    $ RUN SYS$SYSTEM:AUTHORIZE
    UAF> SHOW SYSTEST
     
    Username: SYSTEST                          Owner:  SYSTEST-UETP 
    Account:  SYSTEST                          UIC:    [1,7] ([SYSTEST]) 
    CLI:      DCL                              Tables: DCLTABLES 
    Default:  SYS$SYSROOT:[SYSTEST] 
    LGICMD:   LOGIN 
    Login Flags:  
    Primary days:   Mon Tue Wed Thu Fri Sat Sun 
    Secondary days:                            
    No access restrictions 
    Expiration:            (none)    Pwdminimum:  8   Login Fails:     0 
    Pwdlifetime:         14 00:00    Pwdchange:   22-JUN-2000 10:12 
    Last Login:            (none) (interactive),          (none) (non-interactive) 
    Maxjobs:         0  Fillm:       100  Bytlm:        65536 
    Maxacctjobs:     0  Shrfillm:      0  Pbytlm:           0 
    Maxdetach:       0  BIOlm:        12  JTquota:       1024 
    Prclm:          12  DIOlm:        55  WSdef:          256 
    Prio:            4  ASTlm:       100  WSquo:          512 
    Queprio:         0  TQElm:        20  WSextent:      2048 
    CPU:        (none)  Enqlm:       300  Pgflquo:      20480 
    Authorized Privileges: 
      CMKRNL CMEXEC SYSNAM GRPNAM DETACH DIAGNOSE LOG_IO GROUP 
      PRMCEB PRMMBX SETPRV TMPMBX NETMBX VOLPRO PHY_IO SYSPRV 
    Default Privileges: 
      CMKRNL CMEXEC SYSNAM GRPNAM DETACH DIAGNOSE LOG_IO GROUP 
      PRMCEB PRMMBX SETPRV TMPMBX NETMBX VOLPRO PHY_IO SYSPRV
    UAF> SHOW SYSTEST_CLIG
       .
       .
       .
    UAF> EXIT
    

  2. Make sure the default privileges and quotas assigned to the account match the following list:
    Privileges
    CMKRNL CMEXEC NETMBX DIAGNOSE
    DETACH PRMCEB PRMMBX PHY_IO
    GRPNAM TMPMBX VOLPRO LOG_IO
    SYSNAM SYSPRV SETPRV GROUP

    Quotas
    BIOLM: 18 PRCLM: 12
    DIOLM: 55 ASTLM: 100
    FILLM: 100 BYTLM: 65536
    TQELM: 20 CPU: no limit
    ENQLM: 300 PGFLQUOTA: 20480
    WSDEFAULT: 256 WSQUOTA: 512
    WSEXTENT: 2048  
  3. If any privileges or quotas are incorrect, run AUTHORIZE to correct them.

If you are logged in to the wrong account, the following error message asks you to log in to the SYSTEST account:


$ @UETP
 
**********************
*  UETINIT00         *
*  Error count =  1  *
**********************
-UETP-E-ABORT, UETINIT00 aborted at  22-JUN-2000 14:24:10.13
-UETP-E-TEXT, You are logged in to the wrong account.
              Please log in to the SYSTEST account.
$

You must run UETP from the SYSTEST account.

19.7.3 UETINIT01 Failure

UETINIT01 failures are related to peripheral devices; this type of error message can indicate any of the following problems:

In some cases, the corrective action is specified explicitly in the error message. For example, you can receive a message from the operator communication manager (OPCOM) informing you of a problem and recommending a corrective measure:


%OPCOM,  22-JUN-2000 14:10:52.96, request 1, from user SYSTEST 
Please mount volume UETP in device _MTA0: 
%MOUNT-I-OPRQST, Please mount volume UETP in device _MTA0: 

Other error messages can relate information in which the solution is specified implicitly:


%UETP-S-BEGIN, UETDISK00 beginning at 22-JUN-2000 13:34:46.03 
 
********************** 
*  DISK_DRA          * 
*  Error count =  1  * 
********************** 
-UETP-E-TEXT, RMS file error in file DRA0:DRA00.TST 
-RMS-E-DNR, device not ready or not mounted 
%UETP-S-ENDED, UETDISK00 ended at  22-JUN-2000 13:34:46.80 

This message tells you that a disk drive is either not ready or not mounted. From this information, you know where to look for the cause of the failure (at the disk drive). If you cannot see the cause of the problem immediately, check the setup instructions in Section 19.3.

In other cases, the cause of a failure might not be obvious from the information in the message. The problem can be related to hardware rather than software. For example, the Ethernet adapter test may produce one of the following messages if UETP does not have exclusive access to the Ethernet adapter:

To run the self-test diagnostic on the Ethernet adapter successfully, UETP needs exclusive access to the adapter. As explained in Section 19.3.10, you must shut down DECnet and the LAT terminal server before running the UETP device test phase if you want to test the Ethernet adapter.

Solution

To determine where or when the failure occurs in the execution of UETP, use the following procedure:

19.7.4 UETVECTOR Failure (VAX Only)

UETP displays a message similar to the following one to signal a vector processor failure:


     ********************** 
     *  UETVECTOR         * 
     *  Error count = 1   * 
     ********************** 
     %PPL-S-CREATED_SOME, created some of those requested - partial success 
     -UETP-E-SUBSPNERR, Error spawning subordinate process. 
     -UETP-E-SCHCTXERR, Error scheduling vector context test subprocess. 
     -UETP-E-VECCTXERR, Error encountered during vector context testing. 
%UETP-I-ENDED, UETVECTOR_0000 ended at 22-JUN-2000 07:37:00.59 

Solution

See Section 19.3.19 for the correct setup for vector processor testing.

19.7.5 Device Allocated or in Use by Another Application

If DECnet for OpenVMS software or the LAT software is running during the DEVICE phase, the UETUNAS00 test displays the following message:


-UETP-W-TEXT, Device is in use by DECnet or another application 

Other UETP communication device tests display the following message:


SYSTEM-W-DEVALLOC, device already allocated to another user 

Solution

If you want to run the device test on the Ethernet adapter, shut down DECnet and LAT software before beginning the test.

19.7.6 Insufficient Disk Space

When you run continuous passes of UETP, log files accumulate on the disk from which UETP was run. These files reduce the amount of free disk space available for each successive pass. If the amount of disk space available becomes too small for the current load, the following error message appears:


%UETP-S-BEGIN, UETDISK00 beginning at  22-JUN-2000 08:12:24.34 
%UETP-I-ABORTC, DISK_DJA to abort this test, type ^C 
 
********************** 
*  DISK_DJA          * 
*  Error count = 1   * 
********************** 
-UETP-F-TEXT, RMS file error in file DJA0:DJA00.TST 
-RMS-F-FUL, device full (insufficient space for allocation) 
 
********************** 
*  DISK_DJA          * 
*  Error count = 2   * 
********************** 
-UETP-F-TEXT, RMS file error in file DJA0:DJA01.TST 
-RMS-F-FUL, device full (insufficient space for allocation) 
%UETP-E-DESTP, DISK_DJA stopped testing DJA unit 0 at 08:12:36.91 
%UETP-S-ENDED, UETDISK00 ended at  22-JUN-2000 08:12:37.98 

Solution

Make more space available on the disk. You can do this by using one or more of the following techniques:

See Section 19.2.2 and Section 19.3.3 for a further discussion of disk space.

19.7.7 Incorrect Setup of an OpenVMS Cluster System

Most problems that can occur during the cluster-integration test are related to improper setup of the OpenVMS Cluster system or of UETP on the cluster. These problems are most likely to occur at the following stages of the cluster test:

The cluster test phase shows that various OpenVMS nodes in your cluster can simultaneously access files on selected nodes in the cluster. First, UETP tries to create a file on a disk drive that is accessible to the other selected nodes in the cluster. The following requirements are for creating a file in the cluster test phase:

If UETP is unable to find a suitable device on a certain node, the test displays a warning message and proceeds to the next cluster node.

Nodes on which the operator's terminal (OPA0) is set to the NO BROADCAST terminal characteristic will generate the following error message during the cluster test:


********************** 
*  UETCLIG00master   * 
*  Error count =  1  * 
********************** 
-UETP-E-TEXT, 0 operator consoles timed out on the cluster test warning 
       and 1 operator console rejected it. 
-UETP-E-TEXT, Status returned was, 
      "%SYSTEM-F-DEVOFFLINE, device is not in configuration or not 
      available" 

Disregard this message if OPA0 is set to NO BROADCAST.

Solution

Whenever you suspect a problem, examine the SYS$TEST:NETSERVER.LOG file that was created when the SYSTEST_CLIG process was created. This file can contain additional error information that could not be transmitted to the node running the test. If it was not possible to create the SYSTEST_CLIG process on some node, the system accounting file for that node might contain a final process status in a process termination record.

The following problems can occur during a cluster test: