3.2.2 Read Status Function
The read status function issues a diagnostic status request to the
device, interprets the device response, and returns the response as a
character buffer. If a device definition does not match the device in
the device response, an error message is displayed and the device
definition must be corrected before you can perform an upload function
or download function.
Table 3-6 shows how to access the read status function through the
BASEstar Classic interfaces.
For more information about the READ STATUS command, refer to the
BASEstar Classic Command Line Interface User's Guide. Example 3-3, Example 3-4, Example 3-5,
Example 3-6 and Example 3-7 provide example output of the READ
STATUS command.
Example 3-3 READ STATUS Output for PLC-5 /
250 |
DCM> READ STATUS DTL_5250/FULL
Status of device DTL_5250 at 22-DEC-1999 10:01:10.18
Server: DCM_DTL$SRV_1
Ethernet interface ID: 1
PLC Modes: Run
PLC Type: PLC-5/250 Communication adapters: 5130-RM
Octal station number: 0 Program change sequence: 54
Data change sequence: 18 User data change Sequence: 0
|
Example 3-4 READ STATUS Output for PLC-5 |
DCM> READ STATUS DTL_540/FULL
Status of device DTL_540 at 22-DEC-1999 10:03:02.55
Server: DCM_DTL$SRV_1
Ethernet interface ID: 1
PLC Modes: Rem. program
PLC Type: 1785-L40B (PLC-5/40B) Series B Revision B
Communication adapters: 1785-LT (PLC-5) Octal station number: 3
Memory size in bytes: 98304
Number data table files: 40 Number program files: 5
I/O address if an adapter: 253 Baud rate:
|
Example 3-5 READ STATUS Output for SLC |
DCM> READ STATUS DTL_SLC/FULL
Status of device DTL_SLC at 22-DEC-1999 10:03:20.44
Server: DCM_DTL$SRV_1
Ethernet interface ID: 1
PLC Modes: Rem. program
PLC TYPES: 1747-L541 Series B Revision D
Communication adapters: Domino Plug
SLC500 Ascii Bulletin #: 5/04
SLC500 Major Error Code: 0
SLC500 Comms Active
SLC500 RAM Size in Kbytes: 16
|
Example 3-6 READ STATUS Output for PLC-3 |
DCM> READ STATUS DTL_3/FULL
Status of device DTL_3 at 22-DEC-1999 10:01:01.08
Server: DCM_DTL$SRV_1
Ethernet interface ID: 1
PLC Modes: Program
PLC TYPES: PLC-3 Series A Revision E
Communication adapters: 1775-KA DH port
Current context: 1; Thumbwheel number: 1
Mode control word: 35096
PLC-3 Physical Address of E60.0.0.0: 3574
PLC-3 total number of words in memory: 32768
|
Example 3-7 READ STATUS Output for PLC-2 |
DCM> READ STATUS DTL_2/FULL
Status of device DTL_2 at 22-DEC-1999 10:06:29.33
Server: DCM_DTL$SRV_1
Ethernet interface ID: 1
PLC Modes: Program
PLC TYPES: PLC-2/30 Series A Revision F
Communication adapters: 1771-KA(2)
|
The read status function allows you to verify if the BASEstar Classic
device definition MODEL attribute is compatible with the corresponding
physical device. If the BASEstar Classic definition is not compatible,
the read status function displays an informational message stating what
the actual device is and what it was defined as in BASEstar Classic.