You must use the wwidmgr command to set up each device that you will use for booting or dumping. Once a device is set up, the console retains the information it requires to access the device in nonvolatile memory. You only have to rerun the wwidmgr command if the system configuration changes and the nonvolatile information is no longer valid.
The console provides a simplified setup command, called wwidmgr -quickset. This command can be used in either of the following cases:
If neither description applies to your configuration, refer to the Wwidmgr User's Manual for additional instructions.
Example 7-3 illustrates the wwidmgr -quickset command. Note the following:
| Example 7-3 Using widmgr -quickset | |||
|---|---|---|---|
P00>>>wwidmgr -quickset -udid 10
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d10-0009-8090-0677-0016
via adapter: via fc nport: connected:
dga10.1001.0.2.1 kgpsaa0.0.0.2.1 5000-1fe1-0000-0d14 Yes
dga10.1002.0.2.1 kgpsaa0.0.0.2.1 5000-1fe1-0000-0d11 No
dgb10.1003.0.3.1 kgpsab0.0.0.3.1 5000-1fe1-0000-0d13 Yes
dgb10.1004.0.3.1 kgpsab0.0.0.3.1 5000-1fe1-0000-0d12 No
P00>>>wwidmgr -quickset -udid 50
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d10-0009-8090-0677-0016
via adapter: via fc nport: connected:
dga10.1001.0.2.1 kgpsaa0.0.0.2.1 5000-1fe1-0000-0d14 Yes
dga10.1002.0.2.1 kgpsaa0.0.0.2.1 5000-1fe1-0000-0d11 No
dgb10.1003.0.3.1 kgpsab0.0.0.3.1 5000-1fe1-0000-0d13 Yes
dgb10.1004.0.3.1 kgpsab0.0.0.3.1 5000-1fe1-0000-0d12 No
6000-1fe1-0000-0d10-0009-8090-0677-0026
via adapter: via fc nport: connected:
dga50.1001.0.2.1 kgpsaa0.0.0.2.1 5000-1fe1-0000-0d14 Yes
dga50.1002.0.2.1 kgpsaa0.0.0.2.1 5000-1fe1-0000-0d11 No
dgb50.1003.0.3.1 kgpsab0.0.0.3.1 5000-1fe1-0000-0d13 Yes
dgb50.1004.0.3.1 kgpsab0.0.0.3.1 5000-1fe1-0000-0d12 No
P00>>>initialize
Initializing...
P00>>>show device
polling ncr0 (NCR 53C810) slot 1, bus 0 PCI, hose 1 SCSI Bus ID 7
dka500.5.0.1.1 DKA500 RRD45 1645
polling kgpsa0 (KGPSA-B) slot 2, bus 0 PCI, hose 1
kgpsaa0.0.0.2.1 PGA0 WWN 1000-0000-c920-a7db
dga10.1001.0.2.1 $1$DGA10 HSG80 R024
dga50.1001.0.2.1 $1$DGA50 HSG80 R024
dga10.1002.0.2.1 $1$DGA10 HSG80 R024
dga50.1002.0.2.1 $1$DGA50 HSG80 R024
polling kgpsa1 (KGPSA-B) slot 3, bus 0 PCI, hose 1
kgpsab0.0.0.3.1 PGB0 WWN 1000-0000-c920-a694
dgb10.1003.0.3.1 $1$DGA10 HSG80 R024
dgb50.1003.0.3.1 $1$DGA50 HSG80 R024
dgb10.1004.0.3.1 $1$DGA10 HSG80 R024
dgb50.1004.0.3.1 $1$DGA50 HSG80 R024
polling isp0 (QLogic ISP1020) slot 4, bus 0 PCI, hose 1 SCSI Bus ID 15
dkb0.0.0.4.1 DKB0 RZ1CB-CS 0844
dkb100.1.0.4.1 DKB100 RZ1CB-CS 0844
polling floppy0 (FLOPPY) PCEB - XBUS hose 0
dva0.0.0.1000.0 DVA0 RX23
polling ncr1 (NCR 53C810) slot 4, bus 0 PCI, hose 0 SCSI Bus ID 7
dkc0.0.0.4.0 DKC0 RZ29B 0007
polling tulip0 (DECchip 21040-AA) slot 3, bus 0 PCI, hose 0
ewa0.0.0.3.0 00-00-F8-21-09-74 Auto-Sensing
|
Example 7-4 shows a boot sequence from an FC system disk. Note the following:
| Example 7-4 Boot Sequence from an FC System Disk | |||
|---|---|---|---|
P00>>>set bootdef_dev dga50.1002.0.2.1,dga50.1001.0.2.1,dgb50.1003.0.3.1,
dgb50.1004.0.3.1
P00>>>b
(boot dga50.1002.0.2.1 -flags 0,0)
dga50.1002.0.2.1 is not connected
dga50.1002.0.2.1 is not connected
dga50.1002.0.2.1 is not connected
dga50.1002.0.2.1 is not connected
failed to open dga50.1002.0.2.1
(boot dga50.1001.0.2.1 -flags 0,0)
block 0 of dga50.1001.0.2.1 is a valid boot block
reading 919 blocks from dga50.1001.0.2.1
bootstrap code read in
Building FRU table
base = 200000, image_start = 0, image_bytes = 72e00
initializing HWRPB at 2000
initializing page table at 1f2000
initializing machine state
setting affinity to the primary CPU
jumping to bootstrap code
OpenVMS (TM) Alpha Operating System, Version V7.2
...
$ SHOW DEVICE
Device Device Error Volume Free Trans Mnt
Name Status Count Label Blocks Count Cnt
$1$DGA10: (FCNOD1) Online 0
$1$DGA50: (FCNOD1) Mounted 0 V72_SSB 4734189 303 1
$1$DGA51: (FCNOD1) Online 0
$1$DGA60: (FCNOD1) Online 0
$1$DGA61: (FCNOD1) Online 0
$ SHOW LOGICAL SYS$SYSDEVICE
"SYS$SYSDEVICE" = "$1$DGA50:" (LNM$SYSTEM_TABLE)
$ SHO DEV/MULTI
Device Device Error Current
Name Status Count Paths path
$1$DGA10: (FCNOD1) Online 0 4/ 4 PGB0.5000-1FE1-0000-0D11
$1$DGA50: (FCNOD1) Mounted 0 4/ 4 PGA0.5000-1FE1-0000-0D12
$1$DGA51: (FCNOD1) Online 0 4/ 4 PGA0.5000-1FE1-0000-0D13
$1$DGA60: (FCNOD1) Online 0 4/ 4 PGB0.5000-1FE1-0000-0D14
$1$DGA61: (FCNOD1) Online 0 4/ 4 PGB0.5000-1FE1-0000-0D11
Device Device Error Current
Name Status Count Paths path
$1$GGA42: Online 0 4/ 4 PGB0.5000-1FE1-0000-0D11
|
This section describes the basic requirements for setting up an HSG80 for use with OpenVMS. Refer to the HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide for more information.
These are the steps you must perform to configure an HSG80 for OpenVMS:
You do not need to set the controller's allocation class value. This parameter is not used by OpenVMS with the HSG80. |
You do not need to set the logical unit's preferred path parameter. OpenVMS does not use this value in its path selection. |
To set a dual HSG80 to multibus failover mode, you can use the following commands at the HSG console:
The commands and output are shown in Example 7-5.
| Example 7-5 Setting a Dual HSG80 to Multibus Failover Mode | |||
|---|---|---|---|
HSG> SHOW THIS_CONTROLLER
Controller:
HSG80 ZG80900677 Software R024F-0, Hardware E01
NODE_ID = 5000-1FE1-0000-0D10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Not configured for dual-redundancy
Controller misconfigured -- other controller present
Device Port SCSI address 6
Time: NOT SET
Command Console LUN is disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0D11
PORT_1_PROFILE = SCC
PORT_1_TOPOLOGY = OFFLINE (offline)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0D12
PORT_2_PROFILE = SCC
PORT_2_TOPOLOGY = OFFLINE (offline)
NOREMOTE_COPY
Cache:
128 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
FULLY CHARGED
Expires: 27-APR-2000
NOCACHE_UPS
%CER--HSG> --13-JAN-1946 04:32:49 (time not set)-- Controllers misconfigured. -
Type SHOW THIS_CONTROLLER
HSG> SET MULTIBUS_FAILOVER COPY = THIS_CONTROLLER
%EVL--HSG> --13-JAN-1946 04:38:37 (time not set)-- Instance Code: 07050064 (not
yet reported to host)
Template: 5.(05)
Power On Time: 0. Years, 284. Days, 5. Hours, 18. Minutes, 27. Seconds
Controller Model: HSG80
Serial Number: ZG80900677 Hardware Version: E01(29)
Software Version: R024F(FF)
Informational Report
Instance Code: 07050064
Last Failure Code: 08080000 (No Last Failure Parameters)
%EVL--HSG> --13-JAN-1946 04:38:37 (time not set)-- Instance Code: 43010064 (not
yet reported to host)
Template: 4.(04)
Power On Time: 0. Years, 284. Days, 5. Hours, 18. Minutes, 28. Seconds
Controller Model: HSG80
Serial Number: ZG80900677 Hardware Version: E01(29)
Software Version: R024F(FF)
Informational Report
Other Controller Serial Number: ZG80900641
Failed Controller Target Number: 0.(00)
LUNs Taken By This Controller:
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
Instance Code: 43010064
...
%CER--HSG> --13-JAN-1946 04:38:37 (time not set)-- Received LAST GASP message-
from other controller, Last Failure Code: 08080000
HSG>
...
%CER--HSG> --13-JAN-1946 04:39:23 (time not set)-- Other controller restarted
HSG> SHOW THIS_CONTROLLER
Controller:
HSG80 ZG80900677 Software R024F-0, Hardware E01
NODE_ID = 5000-1FE1-0000-0D10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG80900641
In dual-redundant configuration
Device Port SCSI address 6
Time: NOT SET
Command Console LUN is disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0D11
PORT_1_PROFILE = SCC
PORT_1_TOPOLOGY = OFFLINE (offline)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0D12
PORT_2_PROFILE = SCC
PORT_2_TOPOLOGY = OFFLINE (offline)
NOREMOTE_COPY
Cache:
128 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
FULLY CHARGED
Expires: 27-APR-2000
NOCACHE_UPS
Other controller restarted
|
Example 7-6 shows how to set the HSG80 to SCSI-3 mode. Note that the other controller in a dual configuration is set automatically to the same mode. You must restart the controllers for this operation to take effect.
| Example 7-6 Setting an HSG80 to SCSI-3 Mode | |||
|---|---|---|---|
HSG> SET THIS_CONTROLLER SCSI_VERSION = SCSI-3
Warning 4030: Any units that would appear as unit 0 to a host will not be
available when in SCSI-3 mode
Warning 4020: A restart of both this and the other controller is required
before all the parameters modified will take effect
%CER--HSG> --13-JAN-1946 04:42:28 (time not set)-- Restart of this controller-
required
%CER--HSG> --13-JAN-1946 04:42:28 (time not set)-- Restart of the other-
controller required
Restart of this controller required
Restart of the other controller required
|
You must choose a unique identifier for each device. The following command sets the device identifier for the CCL to 42. This will cause OpenVMS to configure the CCL as a generic SCSI device. The device name will be $1$GGA42. Use the SHOW THIS_CONTROLLER command to verify the setting.
HSG> SET THIS_CONTROLLER IDENTIFIER = 42 |
To set each HSG80 port's profile to PLDA and its topology to FABRIC, use the commands shown in Example 7-7. You can verify the settings with the SHOW THIS and SHOW OTHER commands.
Note that each port has a unique 64-bit identifier in the form 5000-1FE1-0000-0D11. These identifiers are displayed in the SHOW THIS and SHOW OTHER displays, next to the label Reported PORT_ID. These identifiers are used by OpenVMS to denote the multiple paths that may exist between the host and the logical unit.
| Example 7-7 Setting the HSG80 Port Parameters | |||
|---|---|---|---|
HSG> SET THIS_CONTROLLER PORT_1_PROFILE = PLDA
Warning 4000: A restart of this controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:24:09-- Restart of this controller required
Restart of this controller required
HSG> SET THIS_CONTROLLER PORT_1_TOPOLOGY = FABRIC
Warning 4000: A restart of this controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:25:02-- Restart of this controller required
Restart of this controller required
HSG> SET THIS_CONTROLLER PORT_2_PROFILE = PLDA
Warning 4000: A restart of this controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:25:26-- Restart of this controller required
Restart of this controller required
HSG> SET THIS_CONTROLLER PORT_2_TOPOLOGY = FABRIC
Warning 4000: A restart of this controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:25:39-- Restart of this controller required
Restart of this controller required
HSG> SHOW THIS_CONTROLLER
Controller:
HSG80 ZG80900677 Software R024F-0, Hardware E01
NODE_ID = 5000-1FE1-0000-0D10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG80900641
In dual-redundant configuration
Device Port SCSI address 6
Time: 17-MAR-1999 12:25:55
Command Console LUN is lun 0 (IDENTIFIER = 42)
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0D11
PORT_1_PROFILE = PLDA
PORT_1_TOPOLOGY = FABRIC (offline)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0D12
PORT_2_PROFILE = PLDA
PORT_2_TOPOLOGY = FABRIC (offline)
NOREMOTE_COPY
Cache:
128 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
FULLY CHARGED
Expires: 27-APR-2000
NOCACHE_UPS
HSG> SET OTHER_CONTROLLER PORT_1_PROFILE = PLDA
Warning 4010: A restart of the other controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:26:46-- Restart of the other controller required
Restart of the other controller required
HSG> SET OTHER_CONTROLLER PORT_1_TOPOLOGY = FABRIC
Warning 4010: A restart of the other controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:26:59-- Restart of the other controller required
Restart of the other controller required
HSG> SET OTHER_CONTROLLER PORT_2_PROFILE = PLDA
Warning 4010: A restart of the other controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:27:08-- Restart of the other controller required
Restart of the other controller required
HSG> SET OTHER_CONTROLLER PORT_2_TOPOLOGY = FABRIC
Warning 4010: A restart of the other controller is required before all the
parameters modified will take effect
%CER--HSG> --17-MAR-1999 12:27:15-- Restart of the other controller required
Restart of the other controller required
HSG> SHOW OTHER_CONTROLLER
Controller:
HSG80 ZG80900641 Software R024F-0, Hardware E01
NODE_ID = 5000-1FE1-0000-0D10
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG80900677
In dual-redundant configuration
Device Port SCSI address 7
Time: 17-MAR-1999 12:27:31
Command Console LUN is lun 0 (IDENTIFIER = 42)
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0000-0D13
PORT_1_PROFILE = PLDA
PORT_1_TOPOLOGY = FABRIC (offline)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0000-0D14
PORT_2_PROFILE = PLDA
PORT_2_TOPOLOGY = FABRIC (offline)
NOREMOTE_COPY
Cache:
128 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
Not enabled
Battery:
FULLY CHARGED
Expires: 27-APR-2000
NOCACHE_UPS
|
Setting up logical units on the HSG80 consists of the following steps, as shown in Example 7-8:
| Example 7-8 Setting Up Logical Units on the HSG80 | |||
|---|---|---|---|
HSG> RUN CONFIG
Config Local Program Invoked
Config is building its tables and determining what devices exist
on the subsystem. Please be patient.
add disk DISK10000 1 0 0
add disk DISK10100 1 1 0
add disk DISK10200 1 2 0
add disk DISK20000 2 0 0
Config - Normal Termination
HSG> SHOW DISK FULL
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
...
DISK20000 disk 2 0 0
DEC RZ1CD-CS (C) DEC 0306
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 20MHZ (synchronous 20.00 MHZ negotiated)
Size: 8378028 blocks
HSG> SHOW UNITS
No LUNs
HSG> INITIALIZE DISK20000
HSG> ADD UNIT D20 DISK20000
HSG> SET D20 IDENTIFIER = 32020
HSG> SHOW UNITS FULL
LUN Uses Used by
------------------------------------------------------------------------------
D20 DISK20000
LUN ID: 6000-1FE1-0000-0D10-0009-8090-0677-0024
IDENTIFIER = 32020
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
Access:
ALL
State:
ONLINE to this controller
Not reserved
NOPREFERRED_PATH
Size: 8378028 blocks
Geometry (C/H/S): ( 3708 / 20 / 113 )
|
You can allow the HSG80 to create default host-connection information automatically, or you can set host connection information manually, as described in the HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide. If you use the automatic method, you will need to make some changes to the default settings.
Initially, the HSG80 has no host connections. Then, when hosts are connected to the FC interconnect and powered up, the HSG80 detects them and creates default connection information for them, as shown in Example 7-9. After this default information is created, you may want to rename the connections to values that have meaning in your environment, as shown in Example 7-9.
Then, you must:
| Example 7-9 Configuring the HSG80 Host Connections | |||
|---|---|---|---|
HSG> SHOW CONNECTIONS
No Connections
HSG> SHOW CONNECTIONS
Connection Unit
Name Operating system Controller Port Address Status Offset
!NEWCON44 WINNT THIS 2 210713 OL this 0
HOST_ID=1000-0000-C920-A7DB ADAPTER_ID=1000-0000-C920-A7DB
!NEWCON45 WINNT OTHER 2 210713 OL other 0
HOST_ID=1000-0000-C920-A7DB ADAPTER_ID=1000-0000-C920-A7DB
!NEWCON46 WINNT THIS 1 210713 OL this 0
HOST_ID=1000-0000-C920-A694 ADAPTER_ID=1000-0000-C920-A694
!NEWCON47 WINNT OTHER 1 210713 OL other 0
HOST_ID=1000-0000-C920-A694 ADAPTER_ID=1000-0000-C920-A694
HSG> RENAME !NEWCON44 FCNOD1A_T
HSG> RENAME !NEWCON45 FCNOD1A_O
HSG> RENAME !NEWCON46 FCNOD1B_T
HSG> RENAME !NEWCON47 FCNOD1B_O
HSG> SHOW CONNECTIONS
Connection Unit
Name Operating system Controller Port Address Status Offset
FCNOD1A_O WINNT OTHER 2 210713 OL other 0
HOST_ID=1000-0000-C920-A7DB ADAPTER_ID=1000-0000-C920-A7DB
FCNOD1A_T WINNT THIS 2 210713 OL this 0
HOST_ID=1000-0000-C920-A7DB ADAPTER_ID=1000-0000-C920-A7DB
FCNOD1B_O WINNT OTHER 1 210713 OL other 0
HOST_ID=1000-0000-C920-A694 ADAPTER_ID=1000-0000-C920-A694
FCNOD1B_T WINNT THIS 1 210713 OL this 0
HOST_ID=1000-0000-C920-A694 ADAPTER_ID=1000-0000-C920-A694
HSG> SET FCNOD1A_O OPERATING_SYSTEM = VMS
HSG> SET FCNOD1A_T OPERATING_SYSTEM = VMS
HSG> SET FCNOD1B_O OPERATING_SYSTEM = VMS
HSG> SET FCNOD1B_T OPERATING_SYSTEM = VMS
HSG> SHOW CONNECTIONS
Connection Unit
Name Operating system Controller Port Address Status Offset
FCNOD1A_O VMS OTHER 2 210713 OL other 0
HOST_ID=1000-0000-C920-A7DB ADAPTER_ID=1000-0000-C920-A7DB
FCNOD1A_T VMS THIS 2 210713 OL this 0
HOST_ID=1000-0000-C920-A7DB ADAPTER_ID=1000-0000-C920-A7DB
FCNOD1B_O VMS OTHER 1 210713 OL other 0
HOST_ID=1000-0000-C920-A694 ADAPTER_ID=1000-0000-C920-A694
FCNOD1B_T VMS THIS 1 210713 OL this 0
HOST_ID=1000-0000-C920-A694 ADAPTER_ID=1000-0000-C920-A694
|