Document revision date: 19 July 1999
[Compaq] [Go to the documentation home page] [How to order documentation] [Help on this site] [How to contact us]
[OpenVMS documentation]

Volume Shadowing for OpenVMS

Index


Previous Contents


Master Alphabetic Index
A B C D E F G H I K L M N O P Q R S T U V W

A
Addressing data
    recovery from errors
ALLOCATE command
Allocation classes
    naming format
    nonzero
Assisted copy operations
    enabling
    MSCP DCD commands
    See also Copy assists
Assisted merge operations
    performance
AUTOGEN utility
    using with MODPARAMS.DAT file
Availability
    achieved by shadow set configurations
    levels
    of data
    performance impacts
    recovery from failures
    with write I/O requests
B
BACKUP
    See Backup utility
Backup operations
    See also Backup utility
    shadow copy as
    using Backup utility
Backup utility (BACKUP)
    /IMAGE qualifier
    revision number
        used for copy operation
    standalone
        restrictions
Booting
    satellite boot devices
    satellite nodes
    system disk shadow set
C
CI (computer interconnect)
    and MSCP server access to shadow sets
    preventing resource saturation
    shadowing capabilities on
    utilized for copy operations
/CLUSTER qualifier
    mounting a shadow set clusterwide
Cluster systems
    MSCP server access to shadow sets
CLUSTER_CONFIG.COM command procedure
    setting shadowing parameters
CLUSTER_CONFIG_LAN.COM command procedure
    setting shadowing parameters
Compatibility
    between disks and volumes
Computer interconnect
    See CI
Configuration of a shadow set
    cluster with multiple HSJs and star couplers
    effect on availability
    examples
    high-availability local area cluster
    maximum shadow sets #1
    maximum shadow sets #2
    one CPU and one controller
    one CPU and two controllers
    OpenVMS Cluster with dual controllers
Consistency
    data
    ensuring during failures
    when adding shadow set members
Controller errors
    recovery from
Controllers
    performing DCD commands
    setting preferred path
    supporting performance assists
    using performance assists
    write log entries
Conversions
    setting phase II system parameters
Copy assists
    controllers supporting
    disabling
    disabling on HSC controller
    overview
    performance
    setting preferred path
Copy operations
    adding a member
    after a system failure
    BACKUP revision number
    checking
        for proper dismount
        volume label
        volume shadowing generation number
    controlling with the SHADOW_MAX_COPY parameter
    example
    multiple simultaneous
    no copy
    purpose
    recovery from system failures
    transitions in shadow set membership
    with merge operation
/COPY qualifier
Copy threads
    controlling dynamically
    controlling with the SHADOW_MAX_COPY parameter
    referred to in status messages
Crash dumping
    to system disk shadow sets
D
Data
    changing on individual members
Data availability
    See Availability
Data consistency
    when adding shadow set members
Data errors
    recovery from
DCD (disk copy data) commands
DECnet databases
    example of a satellite node
Devices
    allocating
    recovery from controller errors
    recovery from data errors
    recovery from errors
    recovery from failures
    recovery from unit or drive errors
    SCSI support #1
    SCSI support #2
    SCSI support #3
    supported
    unsupported
Digital Storage Architecture
    See DSA #1
    See DSA #2
Digital Storage Systems Interconnect
    See DSSI
Disk mirroring
Disk volumes
    initializing
Disks
    compatibility with volumes
    in Files-11 structure
    initializing
DISMOUNT command
    removing a shadow set member
    required privileges
Dismounting a shadow set
    overview
    with SYS$DISMOU system service
Dismounting a shadow set member
Displaying shadow set information
Dissolving a shadow set
    with SYS$DISMOU system service
Distributing members of shadow sets #1
Distributing members of shadow sets #2
Distributing shadow sets
DOSD, See Dump off system disk
Drive errors
    recovery from
DSA (Digital Storage Architecture)
    naming the virtual unit
    support for compliant hardware #1
    support for compliant hardware #2
DSSI (Digital Storage Systems Interconnect)
    and MSCP server access to shadow sets
Dump off system disk (DOSD) #1
Dump off system disk (DOSD) #2
    use of DUMPSTYLE
DUMPSTYLE system parameter
E
Error messages
    mount verification
    OPCOM
    shadow server
    system service
    VOLPROC
Errors
    recovery from
Ethernet
    and MSCP server access to shadow sets
    preventing resource saturation
    utilized for copy operations
F
F$GETDVI lexical function
    item names
Failovers
    strategy
Failures
    See Recoveries
FDDI (Fiber Distributed Data Interface)
    massively distributed shadowing
Fiber Distributed Data Interface
    See FDDI
Files-11 volume structure
    shadowing support
Forced errors
    checking the SCSI NOFE characteristics
G
GRPNAM privilege
    required for DISMOUNT command
    required for MOUNT command
H
Hardware environment
HSC (hierarchical storage controller)
    disabling performance assists
HSJ (hierarchical storage controller)
    disabling performance assists


Previous Next Contents Index

  [Go to the documentation home page] [How to order documentation] [Help on this site] [How to contact us]  
  privacy and legal statement  
5423PRO_INDEX.HTML