Document revision date: 19 July 1999 | |
Previous | Contents | Index |
Example B-2 is an example of a Lock Contention Log File.
Example B-2 Sample Lock Contention Log File |
---|
*********************************************** Time: 9-JUL-1996 14:23:46.68 Master Node: AXPND1 Resource Name: QMAN$JBC_ALIVE_01 Parent Resource Name: QMAN$MSR_$10$DKA300.....ñ..... RSB Address: 805B1400, GGMODE: EX, CGMODE: EX Hex Representation 514D414E 244A4243 (Bytes 0 - 7) 5F414C49 56455F30 (Bytes 8 - 15) 31000000 00000000 (Bytes 16 - 23) 00000000 000000C0 (Bytes 24 - 31) Status: VALID *********************************************** Time: 9-JUL-1996 14:28:42.44 Resource Name: QMAN$JBC_ALIVE_01 Parent Resource Name: QMAN$MSR_$10$DKA300.....ñ..... Blocking Lock Data Node: AXPND1, PID: 2020008C, Name: JOB_CONTROL LKID: 0200015E, GR Mode: EX Flags: NOQUEUE Local Copy Blocked Lock on WAITING queue Node: AXPND1, PID: 2020008D, Name: QUEUE_MANAGER LKID: 2000013B, RQ Mode: CR Flags: NODLCKW Local Copy *********************************************** |
The following examples show some of the OPCOM messages that appear in the operator log file from the Data Provider:
%%%%%%%%%%% OPCOM 2-JAN-1996 08:16:21.92 %%%%%%%%%%% Message from user RMDRIVER RMA0: - No privilege to access from node 2.2 |
%%%%%%%%%%% OPCOM 2-JAN-1996 10:10:45.08 %%%%%%%%%%% Message from user RMDRIVER RMA0: - No privilege to write from node 2.2 |
%%%%%%%%%%% OPCOM 2-JAN-1996 12:35:05.28 %%%%%%%%%%% Message from user RMDRIVER RMA0: - Process 2390003c modified from node 2.2 |
Following is an alphabetical listing of terms used in this manual and
their definitions.
automatic data collection: Data collection that begins automatically when the Data Analyzer runs and recognizes a Data Provider. By default, this feature is enabled.
The default data windows for which automatic collection is enabled are:
Automatic Event Investigation: Enhances the speed with which you can pursue a specified event. When this option is enabled, DECamds automatically collects follow-up data on the event. When this option is disabled, you must initiate follow-up data collection when an event occurs.
To enable automatic event investigation, choose Enable Automatic Event Investigation from the Control menu of the System Overview or Event Log window. To disable it, choose the Disable Automatic Event Investigation menu item.
This feature does not apply to any lock contention events. To enable
automatic lock contention detection, use the DECamds Application
Customizations dialog box, as explained in Section 5.1.
collection interval: The frequency at which the Data Analyzer will send requests to a Data Provider to collect data.
See also Data Analyzer, Data Provider.
Data Analyzer: The portion of DECamds that collects and displays system data from Data Provider nodes. You can also perform fixes with the Data Analyzer.
See also Data Provider, fix.
Data Provider: The portion of DECamds that is installed to provide system data when requested by authorized Data Analyzers. A Data Provider node uses the OpenVMS LAN drivers to receive and send data across the network.
See also Data Analyzer.
data window: A Data Analyzer window that displays additional data. A number of different data windows are available as follows (see also Chapter 3):
event: A description of a potential resource availability problem, based on rules defined by the Data Analyzer and customized thresholds. Events trigger display changes in data windows such as color and item highlighting.
See also Data Analyzer, data window.
Event Log window: One of two primary Data Analyzer windows that displays events as they occur. For each event, you can display more detailed information to investigate the underlying problem by double-clicking on the event. You can also perform fixes for some events from this window.
See also System Overview window.
fix: A corrective action made to a Data Provider node
but initiated from the Data Analyzer node.
group: A set of remote Data Provider nodes with
similar attributes; for example, all the members of an OpenVMS Cluster
can be in the same group. The group that a node belongs to is
determined by the translation of the AMDS$GROUP_NAME logical on each
Data Analyzer.
occurrence value: The number of consecutive data
samples that must exceed the event threshold before an event is
signaled.
page: A unit used by the operating system to section
memory. On VAX systems, a page is 512 bytes. On Alpha systems, a page
can be 8 kilobytes (8192 bytes), 16 KB, 32 KB, or 64 KB.
pagelet: A unit used by the OpenVMS Alpha operating
system to break down the page into smaller addressable units. One
pagelet is the same as a VAX page: 512 bytes.
security triplet: A three-part access code located in
the AMDS$DRIVER_ACCESS.DAT and AMDS$CONSOLE_ACCESS.DAT files that
enables communications to be established between the Data Analyzer and
Data Provider.
System Overview window: One of two primary Data Analyzer windows that graphically displays groups and the nodes that belong to each group. The System Overview window provides summary data about CPU, Memory, Process I/O usage, Number of Processes in CPU Queues, Operating System Version, and Hardware Model for the nodes being monitored.
Index | Contents |
privacy and legal statement | ||
5929PRO_010.HTML |