Previous Contents Index


$ SET ENTRY nnn/RELEASE/NOCHECKPOINT queue-name

In the command line, supply the following information:
nnn The print job entry number in the queue
queue-name The name of the print queue

The print job will be reprinted from the beginning. Use the PAGE_LIMIT parameter to print only the pages that were not printed before the paper jam occurred.

TRAYSUBST, Output will be delivered to the output-tray tray on printer-name
Explanation: Informational message.
User Action: None.

TRNFAIL, Translation from data-type to PostScript failed.
Explanation: The translator from data-type to PostScript has generated an error. The translator software cannot be used.
User Action: Submit a Software Performance Report (SPR).

TRNNOTFND, Translator from data-type to PostScript not found
Explanation: The DECprint Supervisor software could not find the translator from data-type to PostScript in the SYS$SHARE directory.
User Action: The data type you specified in the DATA_TYPE parameter or that is defined as the queue default must be either supplied by Compaq or a user-written translator (TRN$data-type_PS.EXE in the SYS$SHARE directory). Correct the condition and resubmit the print request.

TRYNOTRDY, tray-name tray on printer-name is current-tray-name
Explanation: The input tray is not loaded with paper.
User Action: Prepare the printer input tray and resubmit the print job.

TUMBNOSUP, printer-name does not support tumble printing
Explanation: The printer does not support tumble printing.
User Action: Resubmit your job without requesting tumble printing. Or resubmit the print job with /QUEUE specifying a printer that supports tumble printing.

TYPCHK, typecheck: Argument of wrong type --- offending command is string
Explanation: The PostScript interpreter sensed this syntax error while trying to execute the PostScript command represented by string.
User Action: If this error occurs during the printing of a file with a data type other than PostScript, an error exists in the translation process. If the translator is supplied by Compaq, submit a Software Performance Report (SPR).

If the error occurs during the printing of a PostScript file, either the PostScript file or the application that generated the PostScript file is in error. If the application is supplied by Compaq, submit a Software Performance Report.

UNDEF, undefined: Name not known --- offending command is string
Explanation: The PostScript interpreter sensed this syntax error while trying to execute the PostScript command represented by string.
User Action: If this error occurs during the printing of a file with a data type other than PostScript, an error exists in the translation process. If the translator is supplied by Compaq, submit a Software Performance Report (SPR).

If the error occurs during the printing of a PostScript file, either the PostScript file or the application that generated the PostScript file is in error. If the application is supplied by Compaq, submit a Software Performance Report.

UNDEFRES, undefinedresult: Number overflow or underflow --- offending command is string
Explanation: The PostScript interpreter sensed an error while trying to execute the PostScript command represented by string.
User Action: If this error occurs during the printing of a file with a data type other than PostScript, an error exists in the translation process. If the translator is supplied by Compaq, submit a Software Performance Report (SPR).

If the error occurs during the printing of a PostScript file, either the PostScript file or the application that generated the PostScript file is in error. If the application is supplied by Compaq, submit a Software Performance Report.

UNDFILNAM, undefinedfilename: File not found --- offending command is string
Explanation: The PostScript interpreter sensed an error while trying to execute the PostScript command represented by string.
User Action: If this error occurs during the printing of a file with a data type other than PostScript, an error exists in the translation process. If the translator is supplied by Compaq, submit a Software Performance Report (SPR).

If the error occurs during the printing of a PostScript file, either the PostScript file or the application that generated the PostScript file is in error. If the application is supplied by Compaq, submit a Software Performance Report.

UNKDATATYPE, Unknown data type: string or translator not available
Explanation: The DECprint Supervisor software does not recognize the DATA_TYPE parameter specified in the PRINT command, or the indicated translator could not be found or started.
User Action: Check the PRINT command, correct the DATA_TYPE parameter, and resubmit your request. If the DATA_TYPE parameter is valid, have your system manager check that the TRN$* translator files listed in the Release NotesRelease Notes are in the correct location on your system and have WORLD:RE protection. Also have your system manager check process-related quotas and resources for the SYSTEM account, if your system is using multistreamed DCPS print symbionts.

UNKFILTAG, File tag is unknown. Tag value: number
Explanation: The file contains a DDIF stored_semantics tag that is not recognized by the DECprint Supervisor software.
User Action: You cannot print this type of file using DECprint Supervisor software.

UNKNOWN_DEFTRANS, data-type is not expected as a Default Translator, but it will be used
Explanation: The data type given by the logical DCPS$queuename_DEFAULT_TRANSLATOR as the default data type is not one that the DECprint Supervisor provides a translator for. The DECprint Supervisor software will attempt to find and use a translator for this data type.
User Action: This message is informational only; the print job is printed. The system manager should ensure that the data type is actually one that is desired. If so, ensure that a translator exists in the SYS$SHARE directory for such a data type. If not, correct the specification of the logical. The queue must be stopped (STOP/QUEUE/RESET) and started (START/QUEUE) for a new definition to take effect.

UNKNOWN_PROLOG, Unknown prolog---version version-number, name prolog-name
Explanation: Dialog between the print symbiont and printer produced unexpected results.
User Action: If you continue to receive this message, call Compaq Customer Services.

UNMATCH, unmatchedmark: Expected mark not on stack --- offending command is string
Explanation: The PostScript interpreter sensed an error while trying to execute the PostScript command represented by string.
User Action: If this error occurs during the printing of a file with a data type other than PostScript, an error exists in the translation process. If the translator is supplied by Compaq, submit a Software Performance Report (SPR).

If the error occurs during the printing of a PostScript file, either the PostScript file or the application that generated the PostScript file is in error. If the application is supplied by Compaq, submit a Software Performance Report.

UNREGIST, unregistered: PostScript has encountered a system error --- offending command is string
Explanation: The PostScript interpreter sensed an error while trying to execute the PostScript command represented by string.
User Action: If this error occurs during the printing of a file with a data type other than PostScript, an error exists in the translation process. If the translator is supplied by Compaq, submit a Software Performance Report (SPR).

If the error occurs during the printing of a PostScript file, either the PostScript file or the application that generated the PostScript file is in error. If the application is supplied by Compaq, submit a Software Performance Report.

UNSUP_DEF_AUTOTYPE, data-type is not supported as an AUTOMATIC data type, assuming AUTOMATIC=ANSI
Explanation: The default text data type defined by the DCPS$[queue-name_]DEFAULT_TRANSLATOR logical name is not a legal value. The legal values are ANSI, PROPRINTER, and PCL.
User Action: The system manager must redefine the logical name.

UNSUP_DEFTRANS, data-type is not supported as a Default Translator, ANSI will be used.
Explanation: The data type assumed by the DECprint Supervisor software as the default text data type is not valid. The DECprint Supervisor software will use ANSI as the default data type.
User Action: The system manager should correct the specification of the logical name DCPS$[queue-name]_DEFAULT_TRANSLATOR. The queue must be stopped (STOP/QUEUE/RESET) and started (START/QUEUE) for a new definition to take effect.

UNSUPTAG, File tagged as data_syntax will not be printed
Explanation: The file contains a DDIF stored_semantics tag that is not supported.
User Action: You cannot print this type of file using the DECprint Supervisor software.

UNSUP_USER_AUTOTYPE, data-type is not supported as an AUTOMATIC data type, assuming AUTOMATIC=ANSI
Explanation: The user's PRINT command, or the default queue parameter in the DCPS$STARTUP.COM command file, specifies the DATA_TYPE=AUTOMATIC=default-text-data-type parameter using an illegal value for default-text-data-type. Legal values are ANSI, PROPRINTER, and PCL.
User Action: If the error was in a PRINT command, resubmit the print job with one of the legal values for the DATA_TYPE=AUTOMATIC parameter.

If the error is in the queue definition, perform the following operations: