Previous | Contents | Index |
This Chapter ... | Explains How To ... |
---|---|
Chapter 5 | Print PostScript files |
Chapter 6 | Print ANSI files |
Chapter 7 | Print DDIF image files |
Chapter 8 | Print PCL files |
Chapter 9 | Print Proprinter files |
Chapter 10 | Print with the LIST data type |
Chapter 11 | Use advanced page layouts |
Chapter 12 | Use layup |
Chapter 13 | Use forms |
Chapter 14 | Use setup modules |
Chapter 15 | Specify file separation pages |
Chapter 16 | Staple output |
Chapter 17 | Use error handler to debug problems |
Chapter 18 | Troubleshoot printing errors |
The PostScript file generated by your application modifies the state of the PostScript interpreter in the printer. The DECprint Supervisor software resets the printer state for each new print job, but not for each file in the print job. Therefore, files that are meant to be printed together, such as a data file with an application prologue or a font, will print successfully. But in a print job with a set of unrelated files, the state of the printer after completing printing of a file may adversely affect the printing of subsequent files.
This can cause PostScript errors and unexpected changes in the
appearance of the printed documents. If you need to print multiple
PostScript files, or multiple copies of a PostScript file, submit them
using separate print jobs.
5.2 Printing Files that Contain Text and PostScript
DECprint Supervisor software can detect PostScript data after the text at the beginning of the file. This is useful for printing PostScript files sent to you by an electronic messaging system that places text in front of the PostScript file.
For example, if you receive a message in a software utility that
generates ANSI text, and that message includes a PostScript file, you
can print the file without specifying the data type.
5.3 Generating Printer-Specific PostScript Files
Each model of PostScript printer recognizes some unique operators that are not part of the standard PostScript language. The PostScript extensions for each PostScript printer may be described in the printer owner's manual.
Many commercial applications, and printer drivers on PC and Macintosh
systems, allow you to specify printer features that depend on
printer-specific extensions (see Section 3.3). For example, you can
create a PostScript file that requires the use of the top input tray on
a particular printer. If you try to print the file on another type of
printer, the file may print from a different tray, or may even fail to
print.
5.4 Resolving Unrecognized PostScript Operator Errors
If you try to print a file that contains a PostScript extension operator that is not defined in your printer, you get the following error message:
%DCPS-W-UNDEF, undefined: Name not known - offending command is operator |
Operator is the PostScript extension operator that is not recognized by the printer.
You may be able to resolve this problem by doing the following:
To generate documents that are independent of printer type, make sure the application that you use to create the PostScript file has printer setup options that do not conflict with the PRINT parameters that you specify with the DECprint Supervisor for OpenVMS software. Use option settings to ensure that your PostScript document is as portable as possible.
To ensure that your application generates documents that are printable on the widest variety of printers:
To ensure sucessful printing from a Microsoft Windows application with the Microsoft PSCRPT.DRV driver, use the following procedure:
LandscapeOrient=270 CtrlD=0 |
This procedure helps you create PostScript documents that are printable
on many printers.
5.5.2 Printing with the Adobe Windows Printer Driver
To avoid wrap problems when printing PostScript output from the Adobe Windows printer driver, follow these steps:
The DECprint Supervisor for OpenVMS software provides example files that show how to
suppress many commonly used PostScript extension operators.
5.6.1 Suppressing PostScript Operators on Desktop Printers
If you are using a desktop printer, you can create a setup module to suppress the failing PostScript operator. The following example file is distributed with the DECprint Supervisor for OpenVMS software:
SYS$COMMON:[SYSHLP.EXAMPLES.DCPS]LPS$STATUSDICT.PS |
This file is an assortment of PostScript routines. You can edit the file and copy routines that solve problems with specific PostScript operators. The new file that you create can be specified as a setup module and printed with the file that failed.
See the DECprint Supervisor for OpenVMS System Manager's Guide for more
information about setup modules.
5.6.2 Suppressing PostScript Operators on PrintServer Printers
The PS_SUPPLEMENT file can be loaded into the PrintServer printer so that many unrecognized PostScript extension operators are ignored. If you have PrintServer Software Version 4.2 or later, this file is automatically downloaded to your printer.
When you submit ANSI or ASCII text files for printing on PostScript
printers, they are translated to PostScript. The DECprint Supervisor software
recognizes the full range of ANSI escape sequences for all levels of
the ANSI printing protocol. Refer to the Digital ANSI-Compliant Printing Protocol Level 3 Programming Reference Manual for more
information about the DIGITAL ANSI-compliant printing protocol and the
functions of the ANSI translator.
6.1 Printing Multiple ANSI Files in a Print Job
ANSI files are handled differently from other types of files. When you
print more than one ANSI file in a print job, the printer commands in
the first file are not passed on to the second file. You must use an
ANSI setup module to pass printing attributes, or include the print
attributes in each file.
6.2 Emulating ANSI Printers
If your site has changed the printing system from ANSI printers to PostScript printers, you can take advantage of the DECprint Supervisor software to print ANSI files that were created for ANSI printers on your new PostScript printers.
The DECprint Supervisor software automatically handles ANSI file printing in a way that emulates printing on ANSI printers. If you need to modify the way that ANSI files are printed, use any of the qualifiers in Table 6-1 to enhance your printed document.
To modify this aspect ... | Use this qualifier ... | To get this effect ... |
---|---|---|
Form feeds, which are usually inserted into the ANSI document at the bottom of each page | /NOFEED | Suppress automatic form feed insertion. |
Header lines on each page | /HEADER 1 | Print the file name, page number, and file creation date at the top of each page. |
Margin, header, and tab processing | /PASSALL | Preserve the state of the file through printing without imposing margins, headers, or tab emulation on the printed document. |
Single-spaced documents | /SPACE 1 | Insert a blank line after each text line, providing double-spaced output. |
Expansion of tabs during processing | /PARAMETERS=[NO]TAB 1 | Control how tabs are processed (see Section 6.3). |
Fonts available for printing | /PARAMETERS=FONTS_USED | Specify one or more SoftFont modules that include software fonts that emulate font cartridges (see Section 6.4). |
Formatting of text by the default form specified for the queue | /FORM | Specify the form definition assumed for the print job. |
The [NO]TAB parameter allows you to emulate the ways in which the ANSI printer handles tab characters. When you include the TAB parameter in your print job, the action is equivalent to using the SET TERMINAL/TAB command on the ANSI printer.
The [NO]TAB parameter is useful when you are not printing 10 characters per inch, or when ANSI tabs are defined in inches, not by character position. If you change the character size, tab sizes do not change when you specify PARAMETERS=TAB. If you expect tabs to change size when characters change size, specify /PARAMETERS=NOTAB.
When you specify [NO]TAB, the software invokes the default form, DCPS$DEFAULT for your job. Refer to Chapter 13 for more information about the default form definition.
By default, the DECprint Supervisor software processes tab characters so that tab stops are set at every eight character positions (/PARAMETERS=NOTAB).
The system manager can change this operation as a queue default so that
you do not have to specify it on the PRINT command line. Different
settings of this parameter may be established as queue defaults for
different generic queues driving the same printer. In this way, you can
access either method of tab expansion when you submit print jobs from
application programs that allow you to specify the queue name but not
the print parameters.
6.4 Emulating Printer Font Cartridges
Your document may require font cartridges in order to print on ANSI printers. If you want to print the document on a PostScript printer, you can use the FONTS_USED parameter to emulate the ANSI printer font cartridges. The files must contain escape sequences that call the fonts.
To include one or more font modules in your print job, use the /PARAMETERS=FONTS_USED qualifier in the PRINT command. For example, if you used to print your file on an ANSI printer with the ITC Souvenir cartridge installed, enter the following command to print it on a PostScript printer with the DECprint Supervisor software:
$ PRINT/PARAMETERS=(FONTS_USED=ITC_SOUV_MCS) file-spec |
If you include two or more cartridge names, be sure to place quotation marks around them. For example:
|
See Appendix D for a list of the available SoftFont kits.
6.5 Using PostScript Operators to Change Trays
With the DECprint Supervisor for OpenVMS software, you can print ANSI documents that were created for printing on media from a specific input tray.
The DECprint Supervisor for OpenVMS software recognizes escape sequences in ANSI files that select the printer input tray. If you print an ANSI file that is set up to select an input tray that does not exist on your printer, the print job fails and you receive the following error message:
%DCPS-W-RANGECHK, rangecheck: Argument out of bounds - offending command is setpapertray. |
If this happens, you can create a PostScript setup module to submit with the print job, and redefine the input tray settings. For example, you could create a PostScript setup module using the following PostScript operators:
/settoptray {statusdict begin 2 setpapertray end} def /setbottomtray {statusdict begin 1 setpapertray end} def |
This example selects the printer tray 2 for the top tray (settoptray), and tray 1 for the bottom tray (setbottomtray). When you create a PostScript setup module, use the operator listed in Table 6-2 that corresponds to the input tray specified in the ANSI file. Select a value for the setpapertray argument that corresponds to an input tray on your printer. Refer to your printer owner's manual for the input tray numbers supported by your printer.
Submit the setup module with your ANSI document using the PRINT command. For example, to use the setup module TRAYDEF.PS to print the file OVERHEAD.TXT, enter the following command:
$ PRINT/NOTIFY/SETUP=TRAYDEF OVERHEAD.TXT |
The ANSI input tray selection sequences and the PostScript operators associated with each of them are listed in Table 6-2. The translator uses the default setpapertray value if no other value has been defined. A setup module with a different value overrides the default value.
ANSI Sequence | User-Defined Operators | Default setpapertray Value |
---|---|---|
CSI ! v | [none] | [none] |
CSI 0 ! v | [none] | [none] |
CSI 1 ! v | settoptray | 1 |
CSI 2 ! v | setbottomtray | 2 |
CSI 3 ! v | setlcittray | 3 |
CSI 4 ! v | setmanualfeedtray | 0 |
CSI 99 ! v | setmanualfeedtray | 0 |
To specify one- or two-sided printing, add ANSI escape sequences to your file. The ANSI duplex sequences are listed in Table 6-3. Replace the sp value in the table with a blank character space in your ANSI file.
ANSI Sequence | Duplex Operation |
---|---|
CSI 0 sp x | true simplex normal |
CSI 1 sp x | true simplex normal |
CSI 2 sp x | true simplex tumbled |
CSI 3 sp x | true duplex normal |
CSI 4 sp x | true duplex tumbled |
CSI 5 sp x | duplex master normal |
CSI 6 sp x | duplex master tumbled |
CSI 7 sp x | simplex compressed normal |
CSI 8 sp x | compressed tumbled |
The LIST data type feature employs a special text-to-PostScript translator (see Chapter 10). It translates 8-bit ASCII (ISO 8859-1) text to a convenient printable form, numbering the lines in the file and printing gray bars behind alternating groups of lines. The LIST translator is not an ANSI translator. It does not translate escape sequences, such as those defined by ANSI PPL3, HP-PCL, or any other printer protocol. You should continue to use the ANSI data type for printing jobs that include and require translation of DEC PPL3 data and control sequences.
Previous | Next | Contents | Index |