Updated: 11 December 1998 |
Order Number: AA--PS6GB--TE
This document describes the features of the VAX MACRO instruction set and assembler. It includes a detailed description of MACRO directives and instructions, as well as information about MACRO source program syntax.
Revision/Update Information: This manual supersedes the VAX MACRO and Instruction Set Reference Manual, Version 6.0
Software Version: OpenVMS VAX Version 7.1
Digital Equipment Corporation Maynard, Massachusetts
Digital Equipment Corporation makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description.
Possession, use, or copying of the software described in this publication is authorized only pursuant to a valid written license from Digital or an authorized sublicensor.
Digital conducts its business in a manner that conserves the environment and protects the safety and health of its employees, customers, and the community.
© Digital Equipment Corporation 1996. All rights reserved.
The following are trademarks of Digital Equipment Corporation: Bookreader, DECdirect, Digital, OpenVMS, VAX, VAX-11/750, VAX-11/780, VAX MACRO, VMS, and the DIGITAL logo.
The following is a third-party trademark:
PostScript is a registered trademark of Adobe Systems Incorporated.
All other trademarks and registered trademarks are the property of their respective holders.
ZK4515
The OpenVMS documentation set is available on CD-ROM.
Contents | Index |
This manual describes the VAX MACRO language and the VAX instruction set. It includes the format and function of each feature of the language. The VAX Architecture Reference Manual describes the instruction set in greater detail.
This manual is intended for all programmers writing VAX MACRO programs. You should be familiar with assembly language programming, the VAX instruction set, and the OpenVMS operating system before reading this manual.
This manual is divided into two parts, each of which is subdivided into several chapters.
Part 1 describes the VAX MACRO language.
Part 2 describes the VAX data types, the instruction and addressing mode formats, and the instruction set.
This manual also contains the following five appendixes:
The following documents are relevant to VAX MACRO programming:
For additional information on the Open Systems Software Group (OSSG) products and services, access the Digital OpenVMS World Wide Web site. Use the following URL:
http://www.openvms.digital.com |
Digital welcomes your comments on this manual.
Print or edit the online form SYS$HELP:OPENVMSDOC_COMMENTS.TXT and send us your comments by:
Internet | openvmsdoc@zko.mts.dec.com |
Fax | 603 881-0120, Attention: OSSG Documentation, ZKO3-4/U08 |
OSSG Documentation Group, ZKO3-4/U08
110 Spit Brook Rd. Nashua, NH 03062-2698 |
Use the following table to order additional documentation or information. If you need help deciding which documentation best meets your needs, call 800-DIGITAL (800-344-4825).
The following conventions are used in this manual:
Ctrl/ x | A sequence such as Ctrl/ x indicates that you must hold down the key labeled Ctrl while you press another key or a pointing device button. |
PF1 x |
A sequence such as PF1
x or GOLD
x indicates that you must first press and release the key
labeled PF1 or GOLD and then press and release another key or a
pointing device button.
GOLD key sequences can also have a slash (/), dash (--), or underscore (_) as a delimiter in EVE commands. |
[Return] | In examples, a key name enclosed in a box indicates that you press a key on the keyboard. (In text, a key name is not enclosed in a box.) |
... |
Horizontal ellipsis points in examples indicate one of the following
possibilities:
|
.
. . |
Vertical ellipsis points indicate the omission of items from a code example or command format; the items are omitted because they are not important to the topic being discussed. |
( ) | In command format descriptions, parentheses indicate that, if you choose more than one option, you must enclose the choices in parentheses. |
[ ] | In command format descriptions, brackets indicate optional elements. You can choose one, none, or all of the options. (Brackets are not optional, however, in the syntax of a directory name in an OpenVMS file specification or in the syntax of a substring specification in an assignment statement.) |
{ } | In command format descriptions, braces indicate a required choice of options; you must choose one of the options listed. |
text style |
This text style represents the introduction of a new term or the name
of an argument, an attribute, or a reason.
This style is also used to show user input in Bookreader versions of the manual. |
italic text | Italic text indicates important information, complete titles of manuals, or variables. Variables include information that varies in system output (Internal error number), in command lines (/PRODUCER= name), and in command parameters in text (where device-name contains up to five alphanumeric characters). |
UPPERCASE TEXT | Uppercase text indicates a command, the name of a routine, the name of a file, or the abbreviation for a system privilege. |
- | A hyphen at the end of a command format description, command line, or code line indicates that the command or statement continues on the following line. |
numbers | All numbers in text are assumed to be decimal, unless otherwise noted. Nondecimal radixes---binary, octal, or hexadecimal---are explicitly indicated. |
VAX MACRO is an assembly language for programming VAX computers using the OpenVMS operating system. Source programs written in VAX MACRO are translated into object (or binary) code by the VAX MACRO assembler, which produces an object module and, optionally, a listing file. The features of the language are introduced in this chapter.
VAX MACRO source programs consist of a sequence of source statements. These source statements may be any of the following:
Instructions manipulate data. They perform such functions as addition, data conversion, and transfer of control. Instructions are usually followed in the source statement by operands, which can be any kind of data needed for the operation of the instruction. The VAX instruction set is summarized in Appendix D of this volume and is described in detail in Chapter 9. Direct assignment statements equate symbols to values. Assembler directives guide the assembly process and provide tools for using the instructions. There are two classes of assembler directives: general assembler directives and macro directives.
General assembler directives can be used to perform the following operations:
Macro directives are used to define macros and repeat blocks. They allow you to perform the following operations:
Use of macros and repeat blocks helps minimize programmer errors and speeds the debugging process.
A source program consists of a sequence of source statements that the assembler interprets and processes, one at a time, generating object code or performing a specific assembly-time process. A source statement can occupy one source line or can extend onto several source lines. Each source line can be up to 132 characters long; however, to ensure that the source line fits (with its binary expansion) on one line in the listing file, no line should exceed 80 characters.
VAX MACRO statements can consist of up to four fields, as follows:
The label field and the comment field are optional. The label field ends with a colon (:) and the comment field begins with a semicolon (;). The operand field must conform to the format of the instruction, directive, or macro specified in the operator field.
Although statement fields can be separated by either a space or a tab (see Table 3-2), formatting statements with the tab character is recommended for consistency and clarity and is a Digital convention.
Field | Begins in Column | Tab Characters to Reach Column |
---|---|---|
Label | 1 | 0 |
Operator | 9 | 1 |
Operand | 17 | 2 |
Comment | 41 | 5 |
For example:
.TITLE ROUT1 .ENTRY START,^M<> ; Beginning of routine CLRL R0 ; Clear register LABT: SUBL3 #10,4(AP),R2 ; Subtract 10 LAB2: BRB CONT ; Branch to another routine |
Continue a single statement on several lines by using a hyphen (-) as the last nonblank character before the comment field, or at the end of a line (when there is no comment). For example:
LAB1: MOVAL W^BOO$AL_VECTOR,- ; Save boot driver RPB$L_IOVEC(R7) |
VAX MACRO treats the preceding statement as equivalent to the following statement:
LAB1: MOVAL W^BOO$AL_VECTOR,RPB$L_IOVEC(R7) ; Save boot driver |
A statement can be continued at any point. Do not continue permanent and user-defined symbol names on two lines. If a symbol name is continued and the first character on the second line is a tab or a blank, the symbol name is terminated at that character. Section 3.3 describes symbols in detail.
Note that when a statement occurs in a macro definition (see Chapter 4 and Chapter 6), the statement cannot contain more than 1000 characters.
Blank lines are legal, but they have no significance in the source program except that they terminate a continued line.
The following sections describe each of the statement fields in detail.
2.1 Label Field
A label is a user-defined symbol that identifies a location in the program. The symbol is assigned a value equal to the location counter where the label occurs. The user-defined symbol name can be up to 31 characters long and can contain any alphanumeric character and the underscore (_), dollar sign ($), and period (.) characters. See Section 3.3.2 for a description of the rules for forming user-defined symbol names in more detail.
If a statement contains a label, the label must be in the first field on the line.
A label is terminated by a colon (:) or a double colon (::). A single colon indicates that the label is defined only for the current module (an internal symbol). A double colon indicates that the label is globally defined; that is, the label can be referenced by other object modules.
Once a label is defined, it cannot be redefined during the source program. If a label is defined more than once, VAX MACRO displays an error message when the label is defined and again when it is referenced.
If a label extends past column 7, place it on a line by itself so that the following operator field can start in column 9 of the next line.
The following example illustrates some of the ways you can define labels:
EXP: .BLKL 50 ; Table stores expected values DATA:: .BLKW 25 ; Data table accessed by store ; routine in another module EVAL: CLRL R0 ; Routine evaluates expressions ERROR_IN_ARG: ; The arg-list contains an error INCL R0 ; increment error count TEST:: MOVO EXP,R1 ; This tests routine ; referenced externally TEST1: BRW EXIT ; Go to exit routine |
The label field is also used for the symbol in a direct assignment
statement (see Section 3.8).
2.2 Operator Field
The operator field specifies the action to be performed by the statement. This field can contain an instruction, an assembler directive, or a macro call.
When the operator is an instruction, VAX MACRO generates the binary code for that instruction in the object module. The binary codes are listed in Appendix D; the instruction set is described in Chapter 9. When the operator is a directive, VAX MACRO performs certain control actions or processing operations during source program assembly. The assembler directives are described in Chapter 6. When the operator is a macro call, VAX MACRO expands the macro. Macro calls are described in Chapter 4 and in Chapter 6 (.MACRO directive).
Use either a space or a tab character to terminate the operator field;
however, the tab is the recommended termination character.
2.3 Operand Field
The operand field can contain operands for instructions or arguments for either assembler directives or macro calls.
Operands for instructions identify the memory locations or the registers that are used by the machine operation. These operands specify the addressing mode for the instruction, as described in Chapter 5. The operand field for a specific instruction must contain the number of operands required by that instruction. See Chapter 9 for descriptions of the instructions and their operands.
Arguments for a directive must meet the format requirements of that directive. Chapter 6 describes the directives and the format of their arguments.
Operands for a macro must meet the requirements specified in the macro definition. See the description of the .MACRO directive in Chapter 6.
If two or more operands are specified, they must be separated by commas (,). VAX MACRO also allows a space or tab to be used as a separator for arguments to any directive that does not accept expressions (see Section 3.5 for a discussion of expressions). However, a comma is required to separate operands for instructions and for directives that accept expressions as arguments.
The semicolon that starts the comment field terminates the operand
field. If a line does not have a comment field, the operand field is
terminated by the end of the line.
2.4 Comment Field
The comment field contains text that explains the function of the statement. Every line of code should have a comment. Comments do not affect assembly processing or program execution. You can cause user-written messages to be displayed during assembly by the .ERROR, .PRINT, and .WARN directives (see descriptions in Chapter 6).
The comment field must be preceded by a semicolon; it is terminated by the end of the line. The comment field can contain any printable ASCII character (see Appendix A).
To continue a lengthy comment to the next line, write the comment on the next line and precede it with another semicolon. If a comment does not fit on one line, it can be continued on the next, but the continuation must be preceded by another semicolon. A comment can appear on a line by itself.
Write the text of a comment to convey the meaning rather than the action of the statement. The instruction MOVAL BUF_PTR_1,R7, for example, should have a comment such as "Get pointer to first buffer," not "Move address of BUF_PTR_1 to R7."
For example:
MOVAL STRING_DES_1,R0 ; Get address of string ; descriptor MOVZWL (R0),R1 ; Get length of string MOVL 4(R0),R0 ; Get address of string |
Next | Contents | Index |